临床试验/NCT01730963
NCT01730963已完成不适用

Multi-Reader Multi-Case Study to Identify Uterine Contractions Recorded From Laboring and Nonlaboring Patients by Practicing Clinicians

Reproductive Research Technologies, LP5 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2007年1月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
30
试验地点
5
主要终点
Comparison of SureCALL® and Tocodynamometer Detection of Contraction Events, as Identified by Readers

研究概览

简要总结

This multi-reader multi-case study was designed to evaluate the performance of SureCALL® Labor Monitor® (SureCALL®) directly to the standard Tocodynamometer device (TOCO).

详细描述

The SureCALL® Labor Monitor® (SureCALL®) is a transabdominal electromyography monitor intended to measure uterine activity. It is intended for use on pregnant women, with singleton pregnancies, using surface electrodes on the maternal abdomen. The device is intended for use by healthcare professionals in a clinical setting.

This multi-reader multi-case study was designed to evaluate the performance of SureCALL® to the predicate Tocodynamometer device (TOCO).

This study involved 25 women at a Gestational Age of 36 weeks or less and 5 women at a Gestation Age of greater than 36 and not in labor at five clinical sites. Each study subject was instrumented with two technologies for measuring uterine activity:

  1. Standard tocodynamometer attached to the maternal abdomen,
  2. SureCALL® with a set of abdominal surface electrodes for uterine electromyography attached to the maternal abdomen

An assessment was obtained and quantified from masked, qualified clinical obstetrician readers for the evaluation of the equivalence of both labor monitor devices by identifying in isolation the individual uterine contraction signals and the peak of each contraction signal as recorded by each labor monitor device.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 40 Years(Adult)
性别
Female
接受健康志愿者
否

入选标准

  • •Singleton Pregnancy
  • •Informed Consent Required

排除标准

  • •Multifetal Pregnancy
  • •Informed Consent Not Given

结局指标

主要结局

Comparison of SureCALL® and Tocodynamometer Detection of Contraction Events, as Identified by Readers

时间窗: 9 - 41 Minutes

Agreement will be assessed by coefficient of individual agreement (CIA) derived from a dataset of all Reader-marked contractions. In addition, sensitivity and false positive rate per hours will be estimated for each patient by each reader. If CIA ≥ 0.445 (Barnhart, 2007, section 3) or CIA\>0.8, Pan 2010), the SureCALL® is not significantly different than the TOCO.