MedPath

rTMS on Mismatch Negativity of Schizophrenia

Not Applicable
Conditions
Mismatch Negativity
Schizophrenia
Interventions
Device: Transcranial magnetic stimulation
Device: Sham
Registration Number
NCT04012684
Lead Sponsor
National Taiwan University Hospital
Brief Summary

Auditory mismatch negativity deficit is a robust neurophysiological biomarker of schizophrenia. Repetitive transcranial magnetic stimulation (rTMS) is a neuromodulation method and can be used to modulate excitability of specific brain cortical region. We hypothesize that MMN deficit of schizophrenia is related to inferior frontal gyrus (IFG) hypofunction, and this deficit can be improved by using rTMS to enhance IFG function.

It is a randomized, double-blinded, sham-controlled clinical trial. Forty-eight schizophrenia patients with MMN deficits (mean amplitude at FCz \> -0.7 ㎶) will be recruited and then randomized at a 1:1 ratio to rTMS group and sham-stimulation group. Subjects in rTMS group will receive high frequency rTMS over IFG, while in the other group subjects will receive sham stimulation at IFG. Frameless stereotaxy navigation will be used to guide the rTMS coil to IFG. The primary outcome is the change of MMN mean amplitude at FCz after stimulation. We hypothesize that the change of MMN mean amplitude is significantly larger in rTMS group than in sham-stimulation group. Their cognitive function and clinical condition will be evaluated carefully before and after experiments.

Detailed Description

Not available

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
48
Inclusion Criteria
  • diagnosis of schizophrenia according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision
  • mean amplitude of MMN at FCz greater than -0.7 ㎶
  • moderate or milder disease severity (scoring 4 or below according to clinical global rating scale)
Read More
Exclusion Criteria
  • unwillingness or inability to cooperate with the experiments
  • with mental retardation, epilepsy, or other major brain pathology (e.g. cerebrovascular accidents or major head injury)
  • with alcohol or other illicit substance abuse
  • with major debilitating systemic diseases or difficulties in ambulation
  • with hearing impairments as screened by audiometry over 500 Hz, 1000 Hz and 6000 Hz
  • with pacemaker, intra-ocular metal foreign body, intracerebral vessel clip, artificial cardiac valve, electronic implant in the body, claustrophobia, or previous surgery involving the brain
  • being pregnant or to be pregnant during the clinical trial. A pre-TMS evaluation scale will be applied to ensure the safety
Read More

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
rTMS: right firstTranscranial magnetic stimulationOne-session rTMS is applied to right IFG. Pre-stimulation and post-stimulation MMN is recorded and compared. After at least two weeks, one-session rTMS is applied to left IFG. Pre-stimulation and post-stimulation MMN is recorded and compared as well. After at least two weeks, stimulations of the same parameters are given over left IFG. Pre-stimulation and post-stimulation MMN is recorded and compared as well.
Sham: right firstShamOne-session sham stimulation is applied to right IFG. Pre-stimulation and post-stimulation MMN is recorded and compared. After at least two weeks, one-session sham stimulation is applied to left IFG. Pre-stimulation and post-stimulation MMN is recorded and compared as well.
rTMS: left firstTranscranial magnetic stimulationOne-session rTMS is applied to left IFG. Pre-stimulation and post-stimulation MMN is recorded and compared. After at least two weeks, one-session rTMS is applied to right IFG. Pre-stimulation and post-stimulation MMN is recorded and compared as well.
Sham: left firstShamOne-session sham stimulation is applied to left IFG. Pre-stimulation and post-stimulation MMN is recorded and compared. After at least two weeks, one-session sham stimulation is applied to right IFG. Pre-stimulation and post-stimulation MMN is recorded and compared as well.
Primary Outcome Measures
NameTimeMethod
Mismatch negativity (MMN)1 day

Mismatch negativity is recorded by electroencephalography and elicited by auditory oddball paradigm in which tone duration deviants are used. MMN is the mean amplitude between 135 and 205 milliseconds after auditory stimuli recorded by electrode FCz.

Secondary Outcome Measures
NameTimeMethod
Wisconsin Card Sorting Test (WCST)1 day

Four indices of WCST are derived: perseverative errors, categories achieved, trials to complete first category, and conceptual level response.

Continuous performance test (CPT)1 day

The undegraded 1-9 task and the 25% degraded 1-9 task are used. Sensitivity indices indicating the ability to discriminate target from non-target trials are calculated (d' for undegraded CPT and md' for degraded CPT).

Trial Locations

Locations (1)

Department of Psychiatry, National Taiwan University Hospital

🇨🇳

Taipei, Taiwan

© Copyright 2025. All Rights Reserved by MedPath