MedPath

Effect of Premodulated Current Versus Diadynamic Current On the Management of Tennis Elbow.

Not Applicable
Completed
Conditions
Tennis Elbow
Interventions
Device: electrical stimulation
Registration Number
NCT05084664
Lead Sponsor
October 6 University
Brief Summary

104 patients with unilateral tennis elbow from both genders (57 females and 43 males) referred by orthopaedist with age ranged between 20 and 60 years.

Detailed Description

hey were recruited in the study from October 2020 to September 2021 and allocated randomly into two groups. Group A received premodulated current in addition to exercises, and group B received diadynamic current with the same exercises. Each patient signed the informed consent form approved by the faculty of physical therapy, October 6 university, Egypt and prospectively registered (Clinical Trials.gov, Identifier NCT03338283). Patients was selected according to the following criteria.

Inclusive criteria

* Patients suffer from pain at the lateral part of the elbow and radiated to the forearm with tenderness increasing on pressure on the lateral epicondyle and on resistance of hand extension

* lasting of the symptoms for 3 months

* no previous physiotherapy interventions.

Exclusive criteria

Internal or external fixation

* arthritis of elbow

* contraindications to electrotherapy like pacemaker, dermatological skin disease, epilepsy, abnormal sensation, and pregnancy.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
104
Inclusion Criteria
  • Patients suffer from pain at the lateral part of the elbow and radiated to the forearm with tenderness increasing on pressure on the lateral epicondyle and on resistance of hand extension
  • lasting of the symptoms for 3 months
  • previous physiotherapy interventions.
Exclusion Criteria
  • Internal or external fixation
  • arthritis of elbow
  • contraindications to electrotherapy like pacemaker, dermatological skin disease, epilepsy, abnormal sensation, and pregnancy.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
group Aelectrical stimulationpremodulated current
group Belectrical stimulationdiadynamic current
Primary Outcome Measures
NameTimeMethod
baseline hydraulic hand dynamometer6 weeks

grip strength measurement (200 lb.90 kg Capacity)

Patient-Rated Tennis Elbow Evaluation (PRTEE)6 weeks

pain and functional measurement (The maximum score is 50 for the pain subscale and 100 for the function subscale)

baseline hydraulic pinch gauge6 weeks

pinch measurement (50 lb.22.5 kg Capacity)

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Bassam

🇪🇬

Qaliubia, Egypt

© Copyright 2025. All Rights Reserved by MedPath