跳至主要内容
临床试验/NCT03977714
NCT03977714已完成不适用

Non-invasive Solution for Periodontal and Peri-implant Diseases

Nanoker Research S.L.2 个研究点 分布在 1 个国家目标入组 24 人开始时间: 2019年8月2日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
24
试验地点
2
主要终点
Implant performance verification: implant survival rate. Change will be assessed.

研究概览

简要总结

DESCRIPTION: The Investigational Product "A-Ce toughened TZP nanocomposite implant" is a Medical Device (MD) intended for the dental rehabilitation of edentulous sites with fixed prosthesis. The "G3®-coated NK2® abutment" is a MD intended for the prevention of peri-implant bone loss due to peri-implantitis. The MD are for dental use and will be used exclusively on subjects who have signed an informed consent form and by approved study investigators.

OBJECTIVES: (a) To evaluate the safety and performance of the "A-Ce toughened TZP nanocomposite Implant" for its intended medical application purpose in the context of successful osseointegration of zirconia-based dental implants. (b) To evaluate the safety and performance of the "G3®-coated NK2® abutment" for its intended purpose in the context of peri-implantitis prevention. (c) To obtain the regulatory CE Mark Certification status for both medical devices.

TYPE OF INVESTIGATION: Randomized double-blind (patient, appraiser) controlled study.

CENTER/COUNTRY: Instituto de Cirugía Oral Avanzada (ICOA), Madrid, Spain

GROUPS:

Group A: 30 zirconia implants with 30 G3-coated abutments (test implant and abutment) Group B: 30 test implants with 30 uncoated (control) abutments Group C: 30 Ti implants (control) with 30 test abutments Group D: 30 control implants with 30 control abutments Group E: 3 test implants and 3 control implants, for histological/histomorphometric evaluation.

COMPARATIVE DEVICE: Commercial Ti dental implant.

STATISTICAL METHODOLOGY:

H0 : INPERIO performs worse (with statistical significance) than the commercial devices.

  • Test implants achieve a higher failure rate than Ti implants.
  • The clinical osseointegration parameter values are worse with statistical significance for test implants than for control implants.
  • Histological and histomorphometric analysis shows worse quality and quantity of osseointegration for test implants than for Ti implants.

H1: There is no statistical significance between INPERIO and the commercial solution or INPERIO performs better (with statistical significance) than the commercial Ti implants.

  • Test implants achieve the same failure rate or less than Ti implants.
  • The clinical osseointegration parameter values are no different or are better with statistical significance for test implants than for control implants.
  • The histological and histomorphometric analysis shows a similar or better quality and quantity of osseointegration for test implants than for Ti implants.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Prevention
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Males/females of age 18-
  • Availability for the 18 months duration of the clinical trial.
  • Subject able and willing to follow study procedures and instructions.
  • Subject read, understood and signed an informed consent form.
  • Participants in need of dental implant treatment and that meet one of the following criteria:
  • Moderate to advanced periodontitis.
  • History of dental loss attributed to periodontitis.
  • Risk factors associated with periodontitis (tobacco consumption, poor oral hygiene, diabetes patients outside of the ideal range control (HbA1c <7)).
  • Good general health at time of inclusion.
  • Subjects willing to disclose information on medication.

排除标准

  • Female patients who report being pregnant or lactating, or who are of childbearing potential and are not using hormonal, barrier methods of birth control or abstinence.
  • Subject chronically treated (≥ two weeks) with any medication known to affect inflammation or periodontal status six months prior to enrollment or during the study.
  • Subject necessitating antibiotic for 1 month during the study.
  • Gross oral pathology.
  • Participation in any other clinical study or test panel within one month prior to entry into the study.
  • History of neoplastic disease requiring the use of chemotherapy.
  • Patients with history of renal failure or chronic renal diseases.
  • Patients affected by chronic liver diseases.
  • Patients with severe or uncontrolled metabolic bone disorders.
  • Conditions or circumstances, in the opinion of the investigator, which could represent a general contra-indication for undergoing surgery, or could prevent study completion or interfere with the analysis of the results, such as a history of non-compliance or unreliability.
  • History of local radiation therapy.

结局指标

主要结局

Implant performance verification: implant survival rate. Change will be assessed.

时间窗: Day 1 (abutment connection), 3 months, 6 months, 1 year.

Number of functional implants vs. number of implants inserted.

Implant performance verification: osseointegration (ex vivo).

时间窗: 2 months after implantation.

Please refer to Arms and Interventions, Experimental: Group E. For ethical reasons, this sample size is limited to six (6) implants, 3 test and 3 controls. Trephined blocks containing the explanted implants will be stored in a 5% formaldehyde solution (pH 7). They will be immersed in a 4% formaldehyde and 1% calcium solution and processed for ground sectioning following the Donath \& Breuner methods. Each implant block will be individualized, embedded in methyl-methacrylate and stained with combined Harris Haematoxyline and Wheatley. The analysis will be performed using a transmitted light microscope equipped with a digital camera. Results will be inferred to clinical osseointegration data, which is the way to assess osseointegration in everyday chairside practice.

Implant performance verification: osseointegration (in vivo). Change will be assessed.

时间窗: Day 1 (abutment connection), 3 months, 6 months, 1 year.

Osseointegration quality: implant stability will be assessed via metal instrument tapping - the transmitted sound will indicate good/bad osseointegration.

G3-coated abutment performance in peri-implantitis prevention. Change will be assessed.

时间窗: Day 1 (abutment connection), 3 months, 6 months, 1 year.

Assessment of peri-implant inflammation sign: bleeding on probing (BOP).

次要结局

  • Prosthetic complications. Change will be assessed.(Day 1 (abutment connection), 3 months, 6 months, 1 year.)

研究者

发起方
Nanoker Research S.L.
申办方类型
Industry
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验