跳至主要内容
临床试验/NCT03191851
NCT03191851已完成不适用

Evaluation of 'Melody' Paracentesis Device for Ascites Therapy in Patients With Cirrhosis (EMPATHY)

University of Nottingham2 个研究点 分布在 1 个国家目标入组 101 人开始时间: 2016年1月4日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
101
试验地点
2
主要终点
Amount of ascites fluid drained (litres)

研究概览

简要总结

Ascites is the accumulation of fluid inside the abdomen. This can happen when the liver fails due to a substantial amount of scarring (cirrhosis). Patients (pts) must have this fluid drained and as cirrhosis progresses, patients will require drainage of ascites repeatedly on a regular basis, leading to frequent hospitals visits and increased complications.

The current drainage device is slow and doesn't always drain completely so pts have to return repeatedly to keep symptoms under control.

A new device (called Melody) has been developed and specifically designed for the purpose of draining ascites fluid, which the Investigators expect to drain faster and completely.

This study will compare the volume of ascites drained using the new 'Melody' catheter device with that used in standard NHS practice. If the melody catheter device is confirmed as superior to the current device this would improve patient experience (less frequent visits to hospital and increased length of time between visits).

With fewer procedures performed per patient, the pressure on the NHS would be greatly reduced in terms of time and costs.

详细描述

Large volume paracentesis has been established as a treatment for symptomatic ascites and is performed regularly in secondary care hospitals widely across the UK.

Lack of a device specifically designed to perform paracentesis means that flow of ascites fluid through the catheter is not optimal leading to incomplete drainage and hence, frequent repeated paracentesis as well as a number of complications.

A new 'Melody' catheter device has been designed and developed in collaboration with Mediplus Ltd and NIHR Enteric Bowel function Healthcare Technology Co-operative; specifically designed to improve the performance characteristics of paracentesis procedure.

(The 'Melody ascites drainage catheter' including 'sterile ascetic drainage sets' is CE marked for clinical use). In addition, investigators would also like to confirm whether the addition of a pump will improve drainage with this device further.

The Investigators propose to carry out a feasibility study, 'EMPATHY', with an aim to compare the performance characteristics of 'Melody' catheter device (with and without addition of 'Andromeda' pump) with the current device. 112 patients with ascites requiring therapeutic paracentesis will be randomised to undergo the procedure using one of the two devices. The volume of ascites drained per session will be compared along with ease of insertion and removal as well as patient experience including all adverse events up to 7 days following the procedure. The outcomes of this feasibility study will inform further refinement of the 'Melody' catheter device as well as a future large multi-centre randomised controlled trial evaluating the cost-effectiveness of the new 'Melody' catheter device in therapeutic paracentesis

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Single Group
主要目的
Supportive Care
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Ascites due to cirrhosis of the liver.
  • Aged 18-80 years.
  • Ability to give written consent.

排除标准

  • Known untreated spontaneous bacterial peritonitis.
  • Disseminated intravascular coagulation at the time of consenting.
  • Pregnancy.
  • Patients who have had more than six ascitic drainage procedures.

结局指标

主要结局

Amount of ascites fluid drained (litres)

时间窗: Up to 6 hours

Amount of ascites fluid drained in one session (litres)

次要结局

  • Adverse Events(Up to 7 days)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验

Evaluation of 'Melody' Paracentesis Device for... | 临床试验