CRUSH STUDY: Calculating Readmission Risk by Ultrasound for Heart Failure Study
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 187
- 试验地点
- 1
- 主要终点
- Change in Corrected Flow Time
研究概览
简要总结
This is a study to determine if two ultrasound measures (Corrected Flow Time and B-Lines) can predict patients at higher risk of readmission within 30 days of hospital discharge for decompensated heart failure.
详细描述
Heart failure (HF) resulting in congestion is the leading cause for admission in persons ≥65 years of age and 20-25% of such patients are readmitted within 30 days of discharge. Efforts to treat HF are difficult without a simple method to detect early signs of congestion to direct therapy. Ultrasound can detect evidence of congestion by increased cardiac filling pressures two weeks prior to other markers of congestion such as weight gain or patient symptoms. Corrected flow time (FTc) measured by ultrasound, is an easy to perform vascular measure and correlates with cardiac filling pressures. Despite the relationship between FTc and filling pressures, this measure has never been studied in HF. The primary aim is to determine if FTc can predict patients at risk of readmission within 30 days. As a secondary aim, the investigators plan to validate a small study of patients reporting the ability of pulmonary ultrasound to predict readmissions. This study demonstrated pulmonary ultrasound was 100% sensitive and 68% specific for predicting readmission at 3 months, however this investigation was small and validation is needed. It is expected ultrasound will be able to accurately and safely predict patients who will be readmitted within 30 days of discharge. This proposal is aimed at identifying a noninvasive measure to better assess congestion from HF and predict readmissions.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •English Speaking
- •Being admitted for heart failure with expected hospital stay of 72 hours
排除标准
- •Unable to provide consent
结局指标
主要结局
Change in Corrected Flow Time
时间窗: Measured daily during hospitalization and then correlated to 30 day readmissions.Mean hospitalization for the study population is 9 days, but will be measured during the duration of their hospitalization.
Daily corrected flow time measures will be obtained during hospitalization. Mean hospitalization time for the study population is 9 days, but will be measured during the duration of their hospitalization. Changes in corrected flow time values will be assessed for associations with 30 day return visits. 30 Day returns will be determined by medical record review as well as follow up phone calls to patients. Corrected Flow Time is a single measure performed serial with the same units of measure.
次要结局
- Change in Pulmonary Ultrasound (B-Lines)(Measured daily during hospitalization and correlated to 30 day readmissions. Mean hospitalization time for the study population is 9 days, but will be measured during the duration of hospitalization.)
研究者
Joseph Pare
Assistant Professor of Emergency Medicine
Boston Medical Center