Digital Evaluation of Accuracy for Removable Partial Denture Frameworks
- Conditions
- DenturePartial
- Interventions
- Other: Selective laser melting framework was fabricated using completely digital workflow
- Registration Number
- NCT06412159
- Lead Sponsor
- Kafrelsheikh University
- Brief Summary
Purpose: To compare the overall accuracy and fit of different components for mandibular metallic removable partial denture (RPD) frameworks fabricated by selective laser melting using combined analog-digital, and fully digital impression techniques.
Material and methods. Two RPD frameworks were fabricated for each of the 18 participants using each of the 2 techniques of the 18 participants enrolled, were of mandibular Kennedy class I, the first technique was the combined analog-digital workflow had the analog steps include: a physical impression was made using polyvinyl siloxane, stone casts were made, then the stone cast was scanned with a laboratory scanner to generate a digital cast. The 3Shape CAD software was then used to design a digital RPD, which was fabricated from a cobalt-chroumum alloy by selective laser melting. The second technique was fully digital where an intraoral digital scanner was used to make a definitive scan, which was sent to the 3Shape software for digitally designing the RPD framework and subsequent selective laser melting for fabrication. For both frameworks in the same participant, the same design was used for consistency. To assess the accuracy of fit, based on STL data analysis (intra-oral digital superimposition evaluation), a color map was constructed using non metrology software, and overall fit accuracy and the misfit (distance between each framework component and the reference intra-oral scan) were measured at rest, guiding plane and lingual plate areas.
- Detailed Description
Eighteen mandibular bilateral partially edentulous participants aged from 50 to 65 years having mandibular Class I Kennedy classification were selected randomly from the outpatient clinic of the prosthodontic department. The clinical study was explained to the patients and they accept it and an informed consent were signed by all them
For each patient, two different cobalt chromium removable partial denture frameworks were constructed; the first one was fabricated using combined analog-digital workflow (group 1) and the other framework was fabricated using completely digital workflow (group 2) and comparing them through evaluation of:
1. Over all accuracy
2. Accuracy of fit of occlusal rests and major connector and Guiding plane/plate relation.
Two techniques were used to fabricate 18 RPD frameworks in total. Fabrication of cobalt chromium removable partial denture framework using combined analog-digital workflow (group 1)
The Removable partial denture frameworks for group 1 were fabricated as follow:
The first technique was a combined analog-digital technique, in which a physical definitive impression was made and a stone cast was fabricated. a physical impression was made using polyvinyl siloxane impression material. , and a stone cast was poured using Type IV stone . In an edentulous area, border molding was first accomplished using a green modeling plastic impression compound . The impression and stone cast were evaluated critically to ensure quality. The stone cast was then scanned using a laboratory scanner to produce a virtual 3D master model. The 3Shape CAD software was used to design a digital RPD . The RPD framework was designed with an lingual plate mandibular major connector, RPI retentive clasps on the first premolars.
The definitive STL design file was then sent to the Dental Laboratory, to be selective laser melted in Co-Cr alloy
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 18
- mandibular Class I Kennedy classification were selected randomly from the outpatient clinic of the prosthodontic department
- other classes of removable partial denture maxillary partially edentulous patients
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- CROSSOVER
- Arm && Interventions
Group Intervention Description selective laser melting removable partial denture frameworks fabricated by conventional technique Selective laser melting framework was fabricated using completely digital workflow selective laser melting removable partial denture frameworks fabricated by conventional technique selective laser melting framework was fabricated using completely digital workflow Selective laser melting framework was fabricated using completely digital workflow selective laser melting framework was fabricated using completely digital workflow
- Primary Outcome Measures
Name Time Method Intra-oral digital Evaluation of fit accuracy for removable partial denture frameworks immediately after insertion of removable partial denture frame work Intra-oral digital Accuracy of fit evaluation between frame works by using medit compare software to exclude the value of point difference in different area at occlusal rest major connector
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Nourhan Ragheb