MedPath

Clinical Efficacy and Safety of Endoscopic Dilatation With Eso-Filp in Benign Esophageal Strictures

Not Applicable
Recruiting
Conditions
Esophageal Cancer
Interventions
Device: Eso-Flip
Registration Number
NCT05725473
Lead Sponsor
Istituto Clinico Humanitas
Brief Summary

Benign esophageal strictures are frequently seen in endoscopic practice and are caused by a variety of esophageal disorders, including peptic, radiotherapy-induced and caustic injuries, Schatzki ring, eosinophilic esophagitis (EoE), and strictures after surgical resection (anastomotic) or endoscopic resection (endoscopic mucosal resection-EMR- and endoscopic submucosal dissection-ESD), and ablative therapies (Radiofrequency, Cryotherapy and Argon-plasma coagulation).

Endoscopic dilation is the first treatment step for benign esophageal strictures. Two types of dilators are available, namely, through-the-scope balloon dilators, with or without a guidewire, and wire-guided bougie dilators. Bougie dilators are used for simple strictures and for strictures in the proximal esophagus, especially anastomotic strictures. Bougie dilators exert a combined radial and longitudinal force, which may increase the risk of perforation. Bougie dilators allow, however, sensing the degree of resistance during dilation, and thereby help determining increasing bougie sizes during next-step dilations. Through the-scope balloon dilators are preferred for complex strictures. Balloons dilators allow direct visualization and control of the radially applied dilation force. In literature, both dilation techniques appear to be equally effective and safe in the management of esophageal strictures, showing no differences in terms of risks of AEs About 30 years ago, the "rule of three" has been published. This rule dictated the extent of dilation during any endoscopic session (i.e., no more than three dilators successively larger than the first dilator to meet resistance were passed) and has been used by endoscopists to reduce the risk of perforation. However, the safety of the "rule of three" has never been demonstrated. Moreover, a recent study suggests that more than three dilation steps per session may be considered for esophageal strictures, with the exception of malignant strictures. The EsoFLIP (Medtronic Inc., Shoreview, MN, USA) is a novel dilation balloon that provides real-time, objective visualization and monitoring of therapeutic dilation. EsoFLIP utilizes high-resolution impedance planimetry to provide real-time measurements (diameter and cross-sectional area) of the stenotic area before, during, and at the end of the dilation without the need of fluoroscopy.

In 2013, technical feasibility and safety of the EsoFLIP in esophago-gastric junction (EGJ) dilation have been demonstrated on porcine models. In a small first pilot study, the technical feasibility of the EsoFLIP device in 10 patients with achalasia has been demonstrated. A second study reported short-term efficacy, both objective (improvement in barium column) and subjective (improvement in Eckardt score), in 28 patients managed using the FLIP hydraulic balloon dilator. Very limited data are currently available in the literature on the use of EsoFLIP in benign esophageal strictures dilation. Potential advantages of the use of EsoFLIP are dilation without fluoroscopy and associated radiation, control of dilation sizes to generate the desired dilation effect and assessment of stricture size and the response to dilatation immediately following dilation.

In a small single centre retrospective study on 19 paediatric patients, use of EsoFLIP hydraulic dilation was safe and provided a larger diameter increase compared with standard balloon dilation, but this was not statistically significant likely because of the small cohort size. The study also suggested that procedure time and fluoroscopy time were shorter in the EsoFLIP cases when compared to other traditional dilation methods. Esophageal dilation using EsoFLIP may yield a larger diameter change increasing the interval between a dilatation procedure and the following one and may potentially reduce procedure time when compared to traditional balloon dilation.

There is currently no published prospective study about dilation with EsoFLIP in adult patients affected by benign esophageal strictures. The endoluminal functional lumen imaging probe, EndoFLIP™ (Medtronic, Minneapolis, MN, USA) (FLIP), is a tool that utilizes impedance planimetry, a technique for performing balloon distention in the alimentary track, to obtain dynamic measurements of any sphincters including the diameter, cross-sectional area (CSA), and distensibility index (DI). Diseases where Endo-FLIP has been employed include esophageal stenosis, reflux esophagitis, eosinophilic esophagitis, gastroparesis, anal sphincter disease, achalasia, and it has also been used in peroral endoscopic myotomy.

Detailed Description

Not available

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
15
Inclusion Criteria
  • Dysphagia due to benign esophageal stricture (e.g. surgery, radiation therapy, caustic ingestion, peptic injury, photodynamic therapy, EoE)
  • A benign esophageal stricture requiring endoscopic esophageal dilation (naïve and refractory to previous treatments)
Exclusion Criteria
  • Patient with known esophageal motility disorder (such as achalasia)
  • Age < 18 years at moment of inclusion in retrospective cohort study
  • Patient unable to give consent to the participation of the clinical study

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Eso-FlipEso-FlipDilatation with Eso-Flip
Primary Outcome Measures
NameTimeMethod
Clinical efficacy12 months

Reduction of severity and frequency of dysphagia (Brief Esophageal Dysphagia Questionnaire, Likert scale, BEDQ)

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Endoscopy Unit, Gastroenterology Department, Humanitas Research Hospital

🇮🇹

Rozzano, Milano, Italy

© Copyright 2025. All Rights Reserved by MedPath