Comparison of Visual Outcomes and Contrast Sensitivity in Patients Implanted With Tecnis Eyhance IOL (Intraocular) and Tecnis Monofocal IOL

Faculty Hospital Kralovske Vinohrady2 个研究点 分布在 1 个国家目标入组 22 人开始时间: 2019年11月12日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
22
试验地点
2
主要终点
Comparison of visual acuity between eyes implanted with EDOF IOL and eyes implanted with monofocal IOL

研究概览

简要总结

To compare visual outcomes for various distances, reading speed, contrast sensitivity, glare occurence, defocus curve and subjective satisfaction in patients implanted with the extended depth of focus lens (Tecnis Eyhance) in one eye and monocal aspheric lens (Tecnis ZCB00) in second eye. Patients undergo visit in 3,6 and 12 months after the surgery.

详细描述

The goal of refractive cataract surgery is to remove the opacity, or cataract and to produce the desired refractive outcome. In most cases, the desired outcome is an emmetropic eye, or an eye that sees 20/20 Snellen for distance vision post-surgery with the implant of a monofocal IOL. This, however, does not offer much in the way of intermediate and near vision. The increased desire for simultaneous distance, intermediate and near vision has increased the popularity of multifocal IOLs (MIOLs). However MIOLs provide visual acuity for all distances, they has occurence of optical phenomena such as glare and halo and lower contrast sensitivity. Extended depth of focus (EDOF) lens should provide distance vision as good as monofocal lens and intermediate vision better than monofocal but without any optical phenomenon or decreased contrast sensitivity.

This study is conducted from 11/2019 to 08/2021 in the Ophthalmology department of Faculty Hospital Kralovske Vinohrady in Prague. The research protocol was explained to all participants and informed consent was signed before enrolling patient to the study. The study was approved by the Ethics Committee of Faculty Hospital Kralovske Vinohrady and will enrolled up to 25 patients with presence of cataract in both eyes.

Bilateral clear corneal phacoemulsification and IOL implantation is performed by one surgeon using the same technique in both eyes. The surgical process involved topical anesthesia, superior 3-step clear corneal incision (2,2mm), 5,0mm curvilinear capsulorhexis, phacoemulsification, bilateral irrigation- aspiration and IOL implantation. One eye is implanted with EDOF IOL second eye with monofocal IOL. Type of IOL is chosen randomly and double masked.

Patients are scheduled for visit at 3,6 and 12 months after the surgery.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Investigator)

盲法说明

Double masked- patient and investigator are masked

入排标准

年龄范围
40 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • presence of cataract in both eyes
  • no other ocular pathology affecting visual acuity
  • bilateral phacoemulsification cataract surgery was arranged for both eyes
  • corneal astigmatism up to 0,75 cylinder (measured by IOL Master biometry)
  • dioptric power of both selective lens within 1,5 D range in one patient
  • selecting IOL power between 18 D and 27 D power range

排除标准

  • complicated cataract
  • corneal opacities or irregularities
  • amblyopia
  • anisometropia
  • coexisting ocular pathologies
  • history of ocular surgery
  • refusal or unable to maintain follow-up

结局指标

主要结局

Comparison of visual acuity between eyes implanted with EDOF IOL and eyes implanted with monofocal IOL

时间窗: 12 months

* uncorrected distance visual acuity (UDVA) * corrected distance visual acuity (CDVA) * uncorrected near visual acuity (UNVA) * distance corrected near visual acuity (DCNVA) * corrected near visual acuity (CNVA) * uncorrected intermediate visual acuity (UIVA) * distance corrected intermediate visual acuity (DCIVA)

Comparison of defocus curve between eyes implanted with EDOF IOL and eyes implanted with monofocal IOL

时间窗: 6 months

A defocus curve that measures visual acuity should be obtained by using the best corrected distance refraction and then defocusing the image in 0.5 increments from +1.5 to -2.5 diopter with spherical plus and spherical minus trial lenses (i.e.,+1.5 D, +1.0 D, +0.5 D, 0.00 D, -0.5 D, -1.00 D, . . . ,-2.50 D) with visual acuity recorded at each change in correction.

Comparison of reading speed between eyes implanted with EDOF IOL and eyes implanted with monofocal IOL

时间窗: 12 months

Monocular reading speed (Salzburg reading desk for 66cm and 80cm)

Difference in contrast sensitivity between eyes with EDOF IOL and monofocal IOL

时间窗: 12 months

Contrast sensitivity - CSV (contrast sensitivity vision) 1000 device- monocularly, mesopic, without glare Contrast sensitivity measurement on Glaretester- monocularly- with and without glare

次要结局

  • Change in reading speed in eyes implanted with EDOF IOL(3 and 12 months)
  • Change in contrast sensitivity in eyes implanted with EDOF IOL(3 and 12 months)
  • Questionaire(6 months)
  • Change in intermediate visual acuity in eyes implanted with EDOF IOL(3 and 12 months)

研究者

发起方
Faculty Hospital Kralovske Vinohrady
申办方类型
Other Gov
责任方
Principal Investigator
主要研究者

Andrea Janekova

MD

Faculty Hospital Kralovske Vinohrady

研究点 (2)

Loading locations...