MedPath

Case Report in Complications After Laparoscopic Transabdominal Preperitoneal Groin Hernia Repair Using LiquiBandFIX8®

Completed
Conditions
Groin Hernia
Registration Number
NCT05952791
Lead Sponsor
Kepler University Hospital
Brief Summary

This an a case report about management and proving the strenght and resistance of LiquiBandFIX8® using for peritoneal closure in a laparoscopic transabdominal preperitoneal groin hernia repair. The patient had anticoagulation due to a mechanical valvula and postoperatively the patient developed a huge hematoma extraperitoneally. Relaparoscopy war performed to identify the problem and check the peritoneal closure.

Detailed Description

This an a case report for proving the strenght and resistance of LiquiBandFIX8® using for peritoneal closure in a laparoscopic transabdominal preperitoneal groin hernia repair (TAPP). The patient had anticoagulation due to a mechanical valvula and postoperatively after TAPP the patient developed a huge hematoma extraperitoneally. The investigatorsperformed relaparoscopy for diagnostic and therapeutic reasons to check stop the bleeding and control the integrety of the peritoneal closure.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
1
Inclusion Criteria
  • Retrospective case report of one patient undergoing laparoscopic groin hernia repair

Exclusion criteria:

  • not applicable (retrospective)
Exclusion Criteria

Not provided

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Hemtoma2 weeks

intraperitoneal blood (yes/no)

Strongness of LiquiBandFIX8®2 weeks

peritoneal leakage, peritoneal damage (yes/no)

Secondary Outcome Measures