Effect of Body Position Changes on Endotracheal Tube Cuff Pressure in Ventilated Critically Ill Patients.

University Hospital, Ghent1 个研究点 分布在 1 个国家目标入组 12 人开始时间: 2011年2月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
12
试验地点
1
主要终点
absolute values of cuff pressure (in cm H20) an number of measurement outside target range.

研究概览

简要总结

The endotracheal tube secures free airway in patients undergoing surgical procedures or mechanical ventilation. The extraluminal airway needs to be sealed by a cuff. The cuff needs to be adequately inflated with air. The cuff pressure should be between 20 and 30 cm H2O. A cuff pressure in excess of the target range is associated with a risk of tracheal injury, whereas a cuff pressure below the lower limit includes a risk of micro-aspiration of subglottic secretions, with risk of subsequent ventilator-associated pneumonia. It is unknown whether the cuff pressure changes following changes in body position of the patient. The objective of this study is to investigate to which extent - if any - cuff pressures change after body position changes of the patient.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 70 Years(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •are age 18 - 70 years, oral intubation with a taperguard EVAC endotracheal tube (Covidien®), conventional mechanical ventilation, adequate sedation (Richmond Agitation-Sedation Scale -5) and analgesia (Behavior Pain Scale 3 to 4).

排除标准

  • •are factors with potential influence on the cuff pressure or factors that disturbed the safety or well-being of the patient: pregnancy, palliative care, difficult intubation, decreased mobility of the neck, history of neck surgery, temperature of <35°C or >37.5°C, morbid obesity (body mass index >35) and every potential contra-indication for position changes such as unstable spinal cord injury or hemodynamic and/or respiratory instability.

研究组 & 干预措施

Cuff pressure after positioning

Experimental

The patient will be positioned in 16 distinct body positions. Immediately after correct positioning, the cuff pressure is measured.

干预措施: cuff pressure (Procedure)

结局指标

主要结局

absolute values of cuff pressure (in cm H20) an number of measurement outside target range.

时间窗: During surgical procedure or mechanical ventilation.

Cuff pressure measurement will be executed with a universal pressure monitor.The patient will be positioned in 16 distinct body positions, immediately after correct positioning, the cuff pressure is measured during an end-expiratory ventilator hold. Cuff pressure is evaluated in the following 16 body positions: anteflexion of the head, hyperextension of the head, left lateral flexion of the head, right lateral flexion of the head, left rotation of the head, right rotation of the head, semirecumbent position with a 45° head of bed elevation, recumbent position with 10° head of bed elevation, horizontal backrest, trendelenburg 10°, left lateral position over 30°, 45° and 90°, and right lateral position over 30°, 45° and 90°.

次要结局

未报告次要终点