MedPath

Variability of Cerebral MRI Diffusion Parameters by Using a Patented Normalization Process vs no Use

Not Applicable
Not yet recruiting
Conditions
Brain MRI
Interventions
Other: Diffusion MRI
Registration Number
NCT05446922
Lead Sponsor
Braintale
Brief Summary

BrainTale has developed a standardization approach based on averaging measurements in predefined brain regions of interest and use of reference data acquired from healthy volunteers under conditions (MRI machine, acquisition protocol) identical to those used for the examination of the patient. The present study is intended to support the normalization step on healthy volunteers in clinical centres that will be equipped with the BrainTale medical device software dedicated to clinical routine practice and to assess, through a multicentre study, the impact of this normalization step on the variability of the MRI diffusion parameters. The data collected will support characterization and modelisation of the variability to explore further biais corrections methods. The study will be conducted by neuroradiologists of the neuroradiology departments of five clinical centres in France.

Detailed Description

Advances in medical imaging have made it possible, from the 1990s, to be able to visualize structural microlesions of the brain thanks to post-processing of the Magnetic Resonance Imaging (MRI) data acquired by the sequence using the diffusion tensor. Mathematical models such as the diffusion tensor have made it possible to quantify in each of the volumetric units of the brain (voxels) measurements correlated to the microstructure of neuronal axons such as the Fractional Anisotropy (FA), the Mean Diffusivity (MD), the Radial Diffusivity (RD) or the Axial Diffusivity (AD). These measurements thus make it possible to quantify the microstructural alterations.

However, the use of Diffusion Tensor Imaging (DTI) technology has limitations and currently, there is no "gold-standard" to validate diffusion measurements, which are currently dependent on acquisition protocols, post-processing software and observers.

To make these diffusion parameters usable in a clinical context, BrainTale has developed a standardization approach based on averaging measurements in predefined brain regions of interest and use of reference data acquired from healthy volunteers under conditions (MRI machine, acquisition protocol) identical to those used for the examination of the patient. This process requires the acquisition of 10 healthy volunteers to calibrate a new MRI protocol, which greatly limits access to the technology in clinical routine and limits the potential technological evolutions of the acquisition.

The study aims to assess the impact of a patented normalization process on the interindividual variability of Fractional Anisotropy (FA) measurements derived from cerebral Diffusion Tensor Imaging (DTI) acquisitions.

A total of 60 healthy volunteers will be included. One or two acquisition will be performed during a single on-site visit in order to collect diffusion parameters outcome data for further analyses (with or without normalization process).

After each acquisition and before inclusion of the following healthy volunteer, anonymised subject's data will be transferred to BrainTale on a secured web platform. BrainTale will be in charge of the Quality Control (QC) of the acquired data and will attribute a QC-passed or QC-failed.

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
All
Target Recruitment
60
Inclusion Criteria
  1. Male or female aged 18 up to 80 years old
  2. Covered by a healthcare insurance
  3. Agreeing to be informed about any incidental finding discovered on brain MRI
  4. Written informed consent form signed
Exclusion Criteria
  1. History of brain pathology, cognitive or psychiatric disorder

  2. Any contraindication * for undergoing brain MRI

  3. Subject refusing to participate or having expressed refusal to data collection/processing or unable to give his/her agreement to participate

  4. Vulnerable subject (i.e. pregnant or breast-feeding woman, child, subject under curatorship or deprived of liberty)

    • contraindications to MRI include: pacemaker, neural stimulator, intraocular or intracerebral device, cochlear implant, MR-incompatible prosthetic heart valves, any implant with metallic, ferromagnetic or electrically conductive parts, any metal in the body which cannot be removed, claustrophobia.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
MRI imaging of 10 healthy volunteersDiffusion MRI10 healthy volunteers will proceed at an brain MRI imaging
Primary Outcome Measures
NameTimeMethod
Coefficients of Variation (%CV) of FA measurementDay 1

Percentage Coefficients of Variation (%CV) of FA measurements obtained from QC-passed DTI sequences before and after application of the normalization process.

Secondary Outcome Measures
NameTimeMethod
Coefficients of Variation (%CV) of AD measurementDay 1

Percentage Coefficients of Variation (%CV) of AD measurements obtained from QC-passed DTI sequences before and after application of the normalization process.

Coefficients of Variation (%CV) of MD measurementDay 1

Percentage Coefficients of Variation (%CV) of MD measurements obtained from QC-passed DTI sequences before and after application of the normalization process.

Coefficients of Variation (%CV) of RD measurementDay 1

Percentage Coefficients of Variation (%CV) of RD measurements obtained from QC-passed DTI sequences before and after application of the normalization process.

© Copyright 2025. All Rights Reserved by MedPath