Cognitive Behavioral Therapy for Insomnia: A Self-Management Strategy for Chronic Illness in Heart Failure
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 195
- 试验地点
- 1
- 主要终点
- Change in Fatigue
研究概览
简要总结
Chronic insomnia may contribute to the development and exacerbation of heart failure (HF), incident mortality and contributes to common and disabling symptoms (fatigue, dyspnea, anxiety, depression, excessive daytime sleepiness, and pain) and decrements in objective and subjective functional performance.
The purposes of the study are to evaluate the sustained effects of CBT-I on insomnia severity, sleep characteristics, daytime symptoms, and functional performance over twelve months among patients who have stable chronic HF and chronic insomnia. The effects of the treatment on outcomes of HF (hospitalization, death) and costs of the treatment will also be examined.
A total of 200 participants will be randomized to 4 bi-weekly group sessions of cognitive behavioral therapy for CBT-I (behavioral was to improve insomnia and sleep) or HF self-management education.
Participants will complete wrist actigraph (wrist-watch like accelerometer) measures of sleep, diaries, reaction time, and 6 minute walk test distance. They will also complete self-report measures of insomnia, sleep, symptoms, and functional performance. In addition the effects on symptoms and function over a period of one year.
详细描述
Almost 75% of HF patients, a group of about 5.1 million Americans who have poor function and high levels of morbidity and mortality, report poor sleep. As many as 25-56% of HF patients report chronic insomnia (difficulty initiating or maintaining sleep or waking early in the morning, with non-restorative sleep that persists for at least a month). Chronic insomnia may contribute to the development and exacerbation of HF and incident mortality. It is also associated with common and disabling symptoms (fatigue, dyspnea, anxiety, depression, excessive daytime sleepiness, and pain) and decrements in objective and subjective functional performance.However, insomnia is under-diagnosed and under-treated in this population.
Cognitive behavioral therapy for insomnia (CBT-I) is a multi-modal behavioral treatment focused on modifying beliefs and attitudes about sleep and is efficacious in many populations. The purposes of RCT are to evaluate the sustained effects of CBT-I, compared with HF self-management education (attention control), on insomnia severity, sleep characteristics, daytime symptoms, and functional performance over twelve months among patients who have stable chronic HF and chronic insomnia and receive evidence-based HF disease management. We will also evaluate the cost-effectiveness of CBT-I compared with the attention-control condition and explore the effects of CBT-I on event-free survival. We will address the following specific aims (*primary outcomes): (1) Test the sustained effects (baseline - 2 weeks, 6, 9, 12 months) of CBT-I provided in 4 group sessions over 8 weeks, compared with HF self-management education (attention control condition), on: (1a) *insomnia severity and self-reported and actigraph-recorded sleep characteristics (*sleep quality, *sleep efficiency, sleep latency, and duration); (1b) symptoms (*fatigue, anxiety, depression, pain, sleepiness, sleep-related impairment), and psychomotor vigilance (PVT); and (1c) symptom clusters [membership in clusters characterized by severity of specific symptoms; transition between clusters over time]; (2) Test the sustained effects of CBT-I on self-reported and objective functional performance; and (3) Examine the cost-effectiveness of CBT-I. Exploratory aim: We will explore the effects of CBT-I on event-free survival.
A total of 200 patients will be randomized to 4 bi-weekly sessions of group CBT-I or an attention control condition consisting of HF self-management education. Wrist actigraph measures of sleep, diaries, psychomotor vigilance and 6 minute walk test distance, and self-report measures of insomnia, sleep, symptoms, and functional performance will be obtained at baseline and follow-up. Data analysis will consist of mixed effects models, latent transition analysis, stochastic cost-effectiveness analysis, and survival analysis.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •stable chronic heart failure, chronic insomnia, English speaking/reading,
排除标准
- •untreated sleep disordered breathing or restless legs syndrome, rotating/night shift work, active illicit drug use, bipolar disorder, neuromuscular conditions affecting the non-dominant arm end-stage renal failure, significant cognitive impairment, unstable medical or psychiatric disorders
研究组 & 干预措施
Cognitive Behavioral Therapy
Cognitive behavioral therapy for insomnia (CBT-I) will be provided in a group format, led by an interventionist. CBT-I includes strategies for modifying thoughts and behaviors about sleep. Participants will be instructed on and practice methods for modifying their thoughts and behaviors about sleep and insomnia. Participants will participate in four sessions, conducted every other week for 8 weeks. They will receive a call from the interventionist on intervening weeks.
干预措施: Cognitive Behavioral Therapy for Insomnia (Behavioral)
Heart Failure Self-Management Education
Heart Failure Self-management education is an intervention that will be provided by a nurse in a group format. This includes standard components, such as education about fluid and sodium management, heart failure medications, diet and physical activity. Participants will participate in four sessions, conducted every other week for 8 weeks. They will receive a call from the interventionist on intervening weeks.
干预措施: Self-Management Education for Heart Failure (Behavioral)
结局指标
主要结局
Change in Fatigue
时间窗: Baseline to 3 months
The symptom of fatigue was measured with the PROMIS Item Bank v1.0 - Fatigue - Short Form 8a. The instrument measures a range of symptoms of fatigue from mild tiredness to exhaustion that may interfere with the performance of daily activities. The instrument uses a 7-day time frame and a 5-point rating scale that ranges from 1 ("Not at all") to 5 ("Very much"). The measure uses a T-score metric in which 50 is the mean of a relevant reference population (the general population) and 10 is the standard deviation (SD) of the population. Higher scores mean more fatigue. To find the total raw score we summed the values of the response to each question. The lowest possible raw score is 8; the highest possible raw score is 40. We used the score conversion table to translate the total raw score into a T-score for each participant. The T-scores are interpreted as follows: Less than 55 = None to slight 55.0-59.9 = Mild 60.0-69.9 = Moderate 70 and over = Severe. The range of scores is 33-78.
Change in Insomnia Severity
时间窗: Baseline to 3 months
Insomnia severity will be measured with the Insomnia Severity Index, a brief self-report instrument measuring patients' perception of their insomnia. The instrument includes 7 items assessing the severity of sleep onset and sleep maintenance difficulties, satisfaction with current sleep pattern, interference with daily functioning, noticeability of impairment attributed to the sleep problem, and degree of distress or concern caused by the sleep problem. Each item is rated on a 0-4 scale (4 indicates greater severity) with a total score ranging from 0 to 28. Scores are categorized as not clinically significant, sub-threshold insomnia, moderate insomnia or severe insomnia. For clarification, when results were entered, the outcome measure title was edited to include "change in" and the time frame was changed to Baseline to 3 months. When registered, the original time frame did not accurately portray the amount of time in which follow up data were collected.
Change in Sleep Efficiency-measured With PSQI
时间窗: Baseline to 3 months
Sleep efficiency refers the ratio of time spent asleep to the amount of time spent in bed. Sleep efficiency will be subjectively measured with the Pittsburgh Sleep Quality Index, an instrument used to calculate self-reported sleep duration, sleep efficiency sleep latency, sleep disturbances, and global sleep quality. Items 1 (bed time), 3 (wake time) are used to determine time-in-bed (the difference between Q1 and Q3). Q4 is time asleep while in bed. Sleep efficiency= (time asleep/time in bed) \* 100 For clarification, when results were entered, the outcome measure title was edited to include "change in" and the time frame was changed to Baseline to 3 months. When registered, the original time frame did not accurately portray the amount of time in which follow up data were collected.
Change in Sleep Efficiency-measured With Actigraphy
时间窗: Baseline to 3 months
Sleep efficiency refers the ratio of time spent asleep to the amount of time spent in bed. Sleep efficiency was objectively measured using actigraphy, a method of inferring sleep from the presence or absence of wrist movement. Participants wore the Respironics Minimitter Actiwatch AW2, a wrist-worn actigraph, to elicit objective sleep efficiency for a two week period. Participants also completed a daily diary (lights out/on, times/purpose of removal, hypnotic use) for use in interpretation of actigraphy data. Sleep efficiency=(time asleep/time in bed) \* 100 For clarification, when results were entered, the outcome measure title was edited to include "change in" and the time frame was changed to Baseline to 3 months. When registered, the original time frame did not accurately portray the amount of time in which follow up data were collected.
Change From Baseline in Fatigue
时间窗: Baseline to 6 months and 12 months
The symptom of fatigue was measured with the PROMIS Item Bank v1.0 - Fatigue - Short Form 8a. The instrument measures a range of symptoms of fatigue from mild tiredness to exhaustion that may interfere with the performance of daily activities. The instrument uses a 7-day time frame and a 5-point rating scale that ranges from 1 ("Not at all") to 5 ("Very much"). The measure uses a T-score metric in which 50 is the mean of a relevant reference population (the general population) and 10 is the standard deviation (SD) of the population. Higher scores mean more fatigue. To find the total raw score we summed the values of the response to each question. The lowest possible raw score is 8; the highest possible raw score is 40. We used the score conversion table to translate the total raw score into a T-score for each participant. The T-scores are interpreted as follows: Less than 55 = None to slight 55.0-59.9 = Mild 60.0-69.9 = Moderate 70 and over = Severe. The range of scores is 33-78.
Change in Sleep Quality
时间窗: Baseline to 3 months
Sleep Quality was subjectively measured with the Pittsburgh Sleep Quality Index, an instrument used to calculate self-reported sleep duration, sleep efficiency sleep latency, sleep disturbances, and global sleep quality. The 19 self-rated items are calculated to provide a global score of sleep quality ranging from 0-21, with "0" indicating no difficulty, and "21" indicating severe difficulty in all areas. For clarification, when results were entered, the outcome measure title was edited to include "change in" and the time frame was changed to Baseline to 3 months. When registered, the original time frame did not accurately portray the amount of time in which follow up data were collected.
Change From Baseline in Insomnia Severity
时间窗: Baseline to 6 months and 12 months
Insomnia severity will be measured with the Insomnia Severity Index, a brief self-report instrument measuring patients' perception of their insomnia. The instrument includes 7 items assessing the severity of sleep onset and sleep maintenance difficulties, satisfaction with current sleep pattern, interference with daily functioning, noticeability of impairment attributed to the sleep problem, and degree of distress or concern caused by the sleep problem. Each item is rated on a 0-4 scale (4 indicates greater severity) with a total score ranging from 0 to 28. Scores are categorized as not clinically significant, sub-threshold insomnia, moderate insomnia or severe insomnia. For clarification, when results were entered, the outcome measure title was edited to include "change in" and the time frame was changed to Baseline to 6 and 12 months. When registered, the original time frame did not accurately portray the amount of time in which follow up data were collected.
Change From Baseline in Sleep Quality
时间窗: Baseline to 6 months and 12 months
Sleep Quality was subjectively measured with the Pittsburgh Sleep Quality Index, an instrument used to calculate self-reported sleep duration, sleep efficiency sleep latency, sleep disturbances, and global sleep quality. The 19 self-rated items are calculated to provide a global score ranging from 0-21, with "0" indicating no difficulty, and "21" indicating severe difficulty in all areas. For clarification, when results were entered, the outcome measure title was edited to include "change in" and the time frame was changed to Baseline to 6 and 12 months. When registered, the original time frame did not accurately portray the amount of time in which follow up data were collected.
Change From Baseline in Sleep Efficiency Measured With PSQI (%)
时间窗: Baseline to 6 months to 12 months
Sleep efficiency refers the ratio of time spent asleep to the amount of time spent in bed. Sleep efficiency will be subjectively measured with the Pittsburgh Sleep Quality Index, an instrument used to calculate self-reported sleep duration, sleep efficiency sleep latency, sleep disturbances, and global sleep quality. Items 1 (bed time), 3 (wake time) are used to determine time-in-bed (the difference between Q1 and Q3). Q4 is time asleep while in bed. Sleep efficiency= (time asleep/time in bed) \* 100 For clarification, when results were entered, the outcome measure title was edited to include "change in" and the time frame was changed to Baseline to 6 and 12 months. When registered, the original time frame did not accurately portray the amount of time in which follow up data were collected.
Change From Baseline in Sleep Efficiency Measured With Actigraphy
时间窗: Baseline to 6 months and 12 months
Sleep efficiency refers the ratio of time spent asleep to the amount of time spent in bed. Sleep efficiency was objectively measured using actigraphy, a method of inferring sleep from the presence or absence of wrist movement. Participants wore the Respironics Minimitter Actiwatch AW2, a wrist-worn actigraph, to elicit objective sleep efficiency for a two week period. Participants also completed a daily diary (lights out/on, times/purpose of removal, hypnotic use) for use in interpretation of actigraphy data. Sleep efficiency=(time asleep/time in bed) \* 100 For clarification, when results were entered, the outcome measure title was edited to include "change in" and the time frame was changed to Baseline to 6 and 12 months. When registered, the original time frame did not accurately portray the amount of time in which follow up data were collected.
次要结局
- Change From Baseline in Sleep Duration(Baseline to 6 months and 12 months)
- Change in Dyspnea(Baseline to 3 months)
- Cost Effectiveness(12 months post treatment)
- Change in Sleep Duration(Baseline to 3 months)
- Change in Anxiety Symptoms(Baseline to 3 months)
- Change in Sleepiness(Baseline to 3 months)
- Change in Sleep Related Impairment(Baseline to 3 months)
- Change From Baseline in Anxiety Symptoms(Baseline to 6 months and 12 months)
- Change in Depressive Symptoms(Baseline to 3 months)
- Change From Baseline in Psychomotor Vigilance(Baseline to 6 months and 12 months)
- Change in Functional Performance(Baseline to 3 months)
- Change From Baseline in Functional Performance(Baseline to 6 months and 12 months)
- Change From Baseline in Depressive Symptoms(Baseline to 6 months and 12 months)
- Change From Baseline in Sleepiness(Baseline to 6 months and 12 months)
- Change From Baseline in Dyspnea(Baseline to 6 months and 12 months)
- Change in Psychomotor Vigilance(Baseline to 3 months)
- Change in Distance (Feet) Traveled During Six Minute Walk Test(Baseline to 6 months and 12 months)
- Change From Baseline in Sleep Related Impairment(Baseline to 6 months and 12 months)
- Change From Baseline in Sleep Latency (Minutes)(Baseline to 6 months and 12 months)
- Change in Sleep Latency(Baseline to 3 months)
- Change in Distance (Feet) Traveled During Six Minute Walk Test(Baseline to 3 months)
