High Quality Imaging and Dosimetry of Yttrium-90 (90Y) SIRT Using a Digital PET/CT

Stanford University2 个研究点 分布在 1 个国家目标入组 42 人开始时间: 2017年2月15日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
42
试验地点
2
主要终点
Image Quality for 90-Y PET/CT Scans

研究概览

简要总结

This clinical trial studies how well yttrium-90 (Y90) glass microspheres positron emission tomography (PET)/computed tomography (CT) works in imaging patients with liver tumors . Images produced by PET/CT may provide better information about the distribution of particles, such as Y90 glass microspheres, delivered for selective internal radiation therapy (SIRT) as compared to regular medical care images useing technetium Tc-99m albumin-aggregated single photon emission computed tomography (SPECT)/CT images.

详细描述

PRIMARY OBJECTIVES:

I. To evaluate the image quality of yttrium-90 (Y90) microspheres PET/CT post SIRT images as compared to technetium Tc-99m albumin aggregated (99mTc MAA) SPECT/CT.

SECONDARY OBJECTIVES:

I. To determine the superior accuracy in both distribution and dosimetry of Y90 PET/CT post-SIRT imaging compared to 99mTc MAA planar and SPECT/CT imaging.

OUTLINE:

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient provides written informed consent
  • Patient is referred for 90Y SIRT radioembolization of liver tumor(s)
  • Patient is capable of complying with study procedures
  • Patient is able to remain still for duration of imaging procedure (approximately 30 minutes total for digital PET/CT)

排除标准

  • Patient is pregnant or nursing

结局指标

主要结局

Image Quality for 90-Y PET/CT Scans

时间窗: 1 day

Image quality for 90Y PET/CT scan images was assessed relative to the expected image quality of Standard of Care (SoC) 99mTc-MAA SPECT/CT scans obtained from the same participant. Assessments were conducted at 5, 10, 15 and 20 minutes after infusion. Scans were assessed on a 1 to 5 Likert scale by 2 Nuclear Medicine physicians who were blinded to patient information. The Likert scale for image quality was established as follows: 1. = Non-diagnostic 2. = Suboptimal 3. = Acceptable 4. = Good 5. = Excellent, equivalent to a SoC 99mTc-MAA SPECT/CT scan The scans for each individual participant at each timepoint was scored on the Likert scale, as determined by the 2 Nuclear Medicine physicians. The outcome is reported as the overall mean of the physician determinations for each time point, with standard deviation.

次要结局

  • Radiopharmaceutical Dosimetry Accuracy for 90-Y PET/CT Scans and 99mTc-MAA SPECT/CT Scans(1 day)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Andrei Iagaru

Professor of Radiology (Nuclear Medicine)

Stanford University