跳至主要内容
临床试验/NCT06389097
NCT06389097招募中不适用

Single-Photon Emission Computed Tomography (SPECT) Imaging for Pharmacokinetics and dosimEtry Towards TREATment Optimization (SEEtoTREAT)

Sidney Kimmel Comprehensive Cancer Center at Johns Hopkins1 个研究点 分布在 1 个国家目标入组 80 人开始时间: 2025年2月3日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
80
试验地点
1
主要终点
Mean absorbed dose to normal organs compared using different quantitative methods

研究概览

简要总结

The investigators will study SPECT imaging of radiopharmaceutical therapies given as standard of care or as part of other compatible research protocols. The goal is to validate the quantitative SPECT image reconstruction methods developed in this proposal, and to investigate the relation between dosimetry calculated from SPECT images and the outcomes. Patients will be recruited for SPECT/CT imaging during treatment. This is an observational study no additional new drugs or activities will be administrated. The investigators will perform SPECT imaging on a total of 80 patients (~20 each from year 2 to year 5). Each participant will be imaged 3 times after the first and last cycles of planned radiopharmaceutical therapy.

详细描述

Radiopharmaceutical therapy (RPT) is an emerging systemic treatment modality that delivers radiation to targeted cells. Recently FDA approved RPT agents include Radium-223 for prostate cancer, 177Lu-DOTATATE for neuroendocrine cancers, and 177Lu-PSMA-617 for prostate cancer. RPT is currently being administered as weight-based or fixed activities for 4-6 cycles, and there is concern that this standardized regimen compromises the potential efficacy of this treatment modality. In large part, this is because rigorous, validated dosimetry methods are not in standard clinical use, especially for alpha emitter RPTs. Such methods using SPECT would make it possible to predict potential normal organ toxicity and tumor response for individual patients. The multidisciplinary Johns Hopkins RPT research group has focused on development of such SPECT dosimetry methods and has an active NIH P01 grant for this work.

The ability to image and understand where the RPT distributes in patients makes it possible to estimate the radiation delivered to tissues. The study team of medical physics experts is developing quantitative 3-D, single-photon emission computed tomography (SPECT) imaging for dosimetry of beta and alpha emitters 1-9. Recognizing that such imaging must be made convenient to be widely adopted, the investigators are also examining the trade-off between simplifying imaging (shorter imaging times, fewer imaging sessions) and the accuracy of the absorbed dose calculations. Key barriers to implementing dosimetry for alpha emitters include the low count-rate and sub-optimal photon emissions and the emission of multiple daughter radionuclides. Currently available reconstruction methods in clinical SPECT systems cannot handle such complex imaging physics. The investigators have pioneered the development of simultaneous multiple radionuclide reconstruction methods for diagnostic applications.

The overall goal of this project is to develop imaging methodologies that may be used to perform accurate RPT dosimetry and treatment planning, especially for alpha emitters. Within this context, the SEE-to-TREAT protocol will provide clinical data and images to validate quantitative reconstruction methods for SPECT imaging.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 100 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Cohort A: Patients with advanced prostate cancer planning to undergo treatment with Radium-223
  • Cohort B: Patients with advanced cancer undergoing treatment with 177Lu-DOTATATE or 177Lu-PSMA-617
  • **Eligible patients may be planning to undergo these treatments as part of standard of care or as part of another research protocol
  • Age > 18 years
  • Eastern Cooperative Oncology Group (ECOG) performance status ≤ 2
  • Histologic confirmation of malignancy

排除标准

  • Patient is participating in another research protocol that does not allow participation in this imaging protocol or that has schedule of procedures that would not be compatible with this protocol.
  • Patient unable to tolerate SPECT scan time, scan frequency, or position.

结局指标

主要结局

Mean absorbed dose to normal organs compared using different quantitative methods

时间窗: 48 months

The mean absorbed dose to normal organs (e.g. kidney) will be calculated for each patient and compared using different quantitative reconstruction methods for SPECT imaging.

次要结局

  • Variability of intra-patient and inter-patient mean absorbed dose to normal organs compared using SPECT images(48 months)
  • Mean absorbed dose to normal organs correlated with toxicity(48 months)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验

SPECT Imaging for Pharmacokinetics and dosimEtry... | 临床试验