1. To compare quality and usability of images taken by two different camera-systems without dilating the pupil.

2. To compare the retinal vessel diameters based on the images of to different camera-systems.

3. To detect changes in retinal vessel diameters while pregnancy and after delivery.

Detailed Description

1. To compare quality and usability of images taken by two different camera-systems without dilating the pupil.

Quality means in this content that images cover the planned region of interest and images should be sharp and good illuminated to see details for medical reading of retinal findings.

2. To compare the retinal vessel diameters based on the images of to different camera-systems.

The diameters of arteries and veins are planned to be measured with an automated software algorithm. Are there differences in the calculated results between the two used camera devices?

3. To detect changes in retinal vessel diameters while pregnancy and after delivery.

Are there detectable changes of the retinal findings between the images taken before and after delivery (e.g. bleeding, edema, vessel tortuosity)

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
214
Inclusion Criteria
  • written informed consent
  • age >18 years
  • pregnancy (only group 2)
Exclusion Criteria
  • limited ability for agreement
  • heavy tremble
  • reduced general condition
  • known epilepsy

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Group 2 Pregnant PopulationRetinal imagingChange in vessel diameter at perinatal visits with retinal imaging (Retinal Imaging, vessel measurements, vessel changes)
Group 1 Standard PopulationRetinal imagingRetinal Imaging, vessel measurements, vessel changes of a population of a female health hospital
Group 1 Standard PopulationVessel measurementsRetinal Imaging, vessel measurements, vessel changes of a population of a female health hospital
Group 1 Standard PopulationChange in vessel diametersRetinal Imaging, vessel measurements, vessel changes of a population of a female health hospital
Group 2 Pregnant PopulationVessel measurementsChange in vessel diameter at perinatal visits with retinal imaging (Retinal Imaging, vessel measurements, vessel changes)
Group 2 Pregnant PopulationChange in vessel diametersChange in vessel diameter at perinatal visits with retinal imaging (Retinal Imaging, vessel measurements, vessel changes)
Primary Outcome Measures
NameTimeMethod
Image Quality12 to 16 month

Visit 1 and Visit 2 (for group 2) Evaluating of image quality for each camera-system

Secondary Outcome Measures
NameTimeMethod
Retinal Pathologies12 to 16 month

Visit 1 and Visit 2 (group 2) Which pathologies / diseases can be assessed with the taken images.

Differences Perinatal12 to 16 month

Visit 1 and Visit 2 (group 2)

Trial Locations

Locations (2)

University Eye Hospital

🇩🇪

Tuebingen, BW, Germany

Female Health Hospital Reutlingen

🇩🇪

Reutlingen, BW, Germany

© Copyright 2025. All Rights Reserved by MedPath