跳至主要内容
临床试验/NCT01180595
NCT01180595已完成4 期

Randomized Control Study Using Roentgen Stereophotogrammetric Analysis (RSA) to Compare the Fixation of the Trabecular Metal Monoblock and the Trabecular Metal Modular Total Knee Arthroplasties

Dalhousie University1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2011年2月1日最近更新:
适应症
干预措施

试验速览

阶段
4 期
状态
已完成
入组人数
50
试验地点
1
主要终点
micromotion of tibial component as measured with RSA

研究概览

简要总结

Total knee replacement is an effective option for treating chronic knee conditions that cause pain and functional impairment. Significant improvements in quality of life, as measured by both disease specific and generic quality of life measures have been well documented. Carefully monitored introduction of new implant designs through small, randomized trials using radiostereometric analysis (RSA) is gaining support. RSA is a radiographic technique that uses small tantalum balls implanted into the patient's bone to measure micromotion (<1 mm) at the bone - implant interface, something which is not possible to do reliably using regular x-ray techniques. The amount of micromotion that occurs within 2 years of surgery can be used to predict the long term survival of knee replacements. This provides a method for detecting inferior implant designs using only a small number of patients before release of these products into large clinical trials.

The study purpose is to utilize RSA to compare the migration patterns of the Trabecular Metal(TM) Monoblock and the TM Modular Total Knee Arthroplasties during the first two postop years and to determine what proportion of cases achieve adequate fixation. Secondary outcome measures will be recorded to quantify changes in functional status of subjects after surgery and bone mineral density will be monitored to quantify any changes around the implant. Migration patterns will be compared to results obtained from previous studies of uncemented and cemented total knee arthroplasty components conducted at this centre.

Null Hypothesis: There is no significant difference in micromotion patterns of the TM arthroplasty components of the monoblock design and the modular design.

Alternative Hypothesis: There are significant differences in micromotion patterns between the tibial components of the monoblock design and the modular design.

This is a consecutive sample randomized control trial of patients undergoing total knee arthroplasty with the TM Monoblock and TM Modular Knee Arthroplasty systems utilizing RSA to identify the migration patterns of the tibial components of the implant. DEXA scanning will also be conducted to determine changes in the bone mineral density adjacent to the implant. Health status and functional outcome measures will be recorded to quantify functional status of subjects before surgery and at each follow-up interval. Gait will be monitored and analyzed preoperatively and postoperatively throughout the duration of the trial.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
21 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Symptomatic osteoarthritis of the knee indicating surgical intervention
  • •Between the ages of 21 and 80 inclusive
  • •Ability to give informed consent

排除标准

  • •Significant co-morbidity affecting ability to ambulate
  • •Flexion contracture greater than 15°
  • •Extension lag greater than 10°
  • •Tibial subluxation greater than 10 mm on standing AP radiograph
  • •Prior arthroplasty, patellectomy or osteotomy with the affected knee
  • •Lateral or medial collateral ligament instability (> 10° varus/valgus)
  • •Leg length discrepancy greater than 10 mm
  • •Active or prior infection
  • •Morbid Obesity (BMI > 40)
  • •Medical condition precluding major surgery
  • •Severe osteoporosis or osteopenia
  • •Neuromuscular impairment

研究组 & 干预措施

Modular

Other

Trabecular Metal Modular Tibial Total Knee Component

干预措施: Trabecular Metal Modular Tibial Total Knee Component (Device)

Monoblock

Other

Trabecular Metal Monoblock Tibial Total Knee Component

干预措施: Trabecular Metal Monoblock Tibial Total Knee Component (Device)

结局指标

主要结局

micromotion of tibial component as measured with RSA

时间窗: 2 years postoperative

次要结局

  • Bone mineral density around the tibial component(2 years postoperative)
  • Subjective health outcome questionnaires - SF36, WOMAC, Oxford12 knee, Pain and Catastrophizing Scale, Standardized comorbidity questionnaire(2 years postoperative)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Michael Dunbar

MD, PhD

Dalhousie University

研究点 (1)

Loading locations...

相似试验