跳至主要内容
临床试验/NCT00822159
NCT00822159终止不适用

Prospective Multicenter Cohort Study to Evaluate the Influence of Bone Strength Measured by DensiProbe Hip on Bone Related Fixation Failure in Patients With Hip Fractures Undergoing DHS Surgical Treatment.

AO Clinical Investigation and Publishing Documentation12 个研究点 分布在 4 个国家目标入组 198 人开始时间: 2008年11月1日最近更新:
适应症

试验速览

阶段
不适用
状态
终止
发起方
入组人数
198
试验地点
12
主要终点
Migration of the screw in relation to the femoral head of 5 mm or more and/or Telescoping (shortening of the femoral neck) of 10 mm or more

研究概览

简要总结

Hip fractures mostly occur in elderly people with low bone strength. Bone strength is determined by bone mineral density (BMD), bone turnover, microarchitectural and geometrical properties of the bone. Dual energy x-ray absorptiometry (DXA) is the standard technique to measure BMD. However, BMD just provides information regarding the quantity of mineral in bone, which is only one component of bone strength. To date there is no reliable method to assess bone strength in vivo. Therefore, a method to assess bone strength beyond BMD would provide additional information regarding the patients' risk of bone related fixation failure after fracture fixation.

DensiProbe is a new diagnostic device that was developed for intra-operative assessment of mechanical stability of the bone in the proximal femur. It consists of a drill bit like tool and an electronic system to measure the peak torque to break-away of trabecular bone in the femoral head of patients undergoing DHS surgical treatment. In a cadaver study comparing bone mineral density measured by quantitative computed tomography with bone strength measured by DensiProbe a high correlation between these two parameters could be shown. In a clinical pilot study a significant correlation between DensiProbe measurements and BMD measured by DXA at the femoral neck in patients with hip fractures could be shown. However, no perfect correlation was expected because DensiProbe measures bone strength, which is only partly caused by BMD.

Bone related fixation failure, such as secondary loss of reduction, is influenced by bone strength, bone mineral density, fracture type, fracture reduction and primary positioning of the implant. The predictive value of DensiProbe measurements for secondary loss of reduction needs to be investigated. If DensiProbe turned out to be an effective screening tool for patients with low bone strength that are on higher risk of the aforementioned complications these patients may in future benefit from alternative treatment methods (e.g. augmentation techniques) in order to reduce bone related fixation failure.

The primary aim of the present study is to investigate if bone strength measured by DensiProbeTM Hip (DensiProbe) is an independent factor to predict secondary loss of reduction (screw migration of 5 mm or more and / or telescoping of 10 mm or more) in patients with hip fractures after fracture fixation with DHS.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
50 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients 50 years or older
  • Patients with trochanteric or femoral neck fractures, classified as: AO 31-A1, AO 31-A2, AO 31-A3, AO 31-B1, AO 31-B2, AO 31-B3
  • Patients undergoing fixation with DHS (135° aiming device, anti-rotational K-wire)
  • Patients willing to participate in the study according to the clinical investigation plan
  • Patients able to understand and read country national language at an elementary level
  • Signed written informed consent by the patient or legal guardian

排除标准

  • Bilateral hip fractures (at present or in the past)
  • Open hip fracture
  • Any previous surgical procedures of the hip (ipsilateral / contralateral)
  • More than 7 days between injury and surgery
  • Polytrauma (multiple injuries, whereof one or the combination of several injuries is life-threatening)
  • Patients being pregnant or breast-feeding
  • Pathologic fractures
  • Active malignancy
  • Psychiatric disorders that would preclude reliable assessment (e.g. severe depression)
  • Drug or alcohol abuse
  • Patients having participated in any other device or drug related clinical trial within the previous month

结局指标

主要结局

Migration of the screw in relation to the femoral head of 5 mm or more and/or Telescoping (shortening of the femoral neck) of 10 mm or more

时间窗: 3 months

次要结局

  • Rate of complications(3 months)
  • BMD values measured by DXA (contralateral hip)(Post OP)
  • Parker mobility score(3 months)

研究者

发起方
AO Clinical Investigation and Publishing Documentation
申办方类型
Other
责任方
Sponsor

研究点 (12)

Loading locations...

相似试验

Influence of Bone Strength Measured by DensiProbe on... | 临床试验