Study of SelfFit App for Hearing Loss Diagnostics Based on Threshold Measurements Through In-situ Audiometry and Adjustment of Hearing Device Amplification Parameters in Agreement With Prescriptive Formulas as NAL-NL1,DSL-i/o
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 20
- 试验地点
- 2
- 主要终点
- Hearing threshold
研究概览
简要总结
The purpose of this clinical study is to validate the comparability of prescription formula fitting of hearing aids based on full diagnostic audiometry and SelfFit interactive fitting of hearing aids based on hearing loss screening (mild to moderate hearing losses) using in-situ audiometry, provided and executed through the mobile medical app.
详细描述
The technology utilized within the mobile medical App is partially described in the US patent application US2011/0002490A1. The app is to be used in combination with a hearing aid to deliver the output and targets accurate individual acoustical amplification for effective compensation of a users hearing loss.
The electronic circuitry incorporating the digital signal processing algorithms - dynamic range compression, noise reduction - is providing the acoustical amplification according to parameters (acoustical gain, compression ratio, time constants) calculated through the App on base of in-situ hearing loss diagnostics (pure tone audiometry, loudness scaling). Within the study, amplification parameters will be transmitted to the prototyped device through a prototyped audio streaming box.
Individual audiogram represents hearing thresholds (softest audible sounds) at different frequencies. At least two test frequencies are used involving one in the lower region of device's bandwidth (such as 750 Hz) and one in the higher region of the device's bandwidth (such as 2 kHz). Hearing thresholds are assessed by presenting pure tones of different known levels (SPL) to the user and the thresholds for each of the test frequencies are determined according to the user response to a verbally formulated question (how many tones did you hear?) and multiple choice answer buttons (0, 1, or 2).
Second hearing loss characteristic obtained by the app. is the personal loudness scaling. By presenting a band-limited noise stimuli and collecting the user response about perceived loudness level Medical Mobile App calculates dynamic range of users hearing at given frequency.
The calculation of optimal amplification parameters is performed by App using a proprietary "fitting formula" derived from scientific data.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Hearing loss at the better ear between 35dB and 50dB (PTA1/2/4)
- •Active lifestyle
- •No language problems
- •No medical contra-indications
- •Age: between 18 and 75 years
- •About 50% experienced users and 50% new users
- •Willing to participate in the trial with one three hour visit to the AMC.
排除标准
- •Conductive hearing loss in the middle ear
- •Severe hearing loss
结局指标
主要结局
Hearing threshold
时间窗: June - July 2013 (up to 2 months)
Applicability of in-situ audiometry: Comparison of pure tone audiometry outcomes: conventional full diagnositic and SelfFit in-situ audiometry
次要结局
- Speech intelligibility - First Fit(June - July 2013 (up to 2 months))