Study of Somatosensory Responses During Millimeter Waves Application
- Conditions
- Healthy Volunteers
- Interventions
- Device: Millimeter waves local exposure
- Registration Number
- NCT04801550
- Lead Sponsor
- University Hospital, Grenoble
- Brief Summary
The brain activity induced by a sensory stimulus and measured by magnetoencephalography will be compared before and after exposure to millimeter waves. We hypothesize that brain activity is modified after exposure to millimeter waves. The neuromodulatory effects of millimeter waves may lead to future development on therapeutic management in anxiety and pain.
- Detailed Description
Several studies showed clinical efficacy of millimeter waves in pain management, with no side-effects.
However, its mechanism of action is still partly unknown. Preclinical studies showed that the use of millimeter waves near highly-innervated areas stimulates subcutaneous receptors, even at low power.
To achieve safe millimeter wave stimulation, we will use a bracelet (Remedee Labs) emitting millimeter waves, that has been developped for human use. It complies with radiofrequency exposure regulation (CE-marked).
This study aims to provide a better understanding of the mechanism by which millimeter waves interact with somatosensory system in brain.
For this purpose, the analysis of brain activity will focus on somatosensory responses elicited by electrical stimulation of the right thumb.
Subjects will complete two sessions during which the brain activity will be recorded by magnetoencephalography (MEG) before, during and after the use of a bracelet emitting millimeter waves.
Magnetoencephalography is chosen for its good temporal resolution, its sensitivity in the low frequencies and its accuracy to locate neural sources when matching with an Magnetic Resonance (MR) Imagery. It will allow us to study the shape and the delay of the somatosensory response in primary somatosensory cortex (SI) and secondary somatosensory cortex (SII) cortical areas of the brain.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- Male
- Target Recruitment
- 10
- Healthy male voluntary subject, aged 18 to 40 inclusive.
- Right-handed subject verified by the Edinburgh test.
- Body mass index (BMI) between 18 and 25 kg/m2 inclusive.
- Blood pressure and heart rate considered clinically normal by the investigators.
- Having benefited from a medical examination before participating in the research.
- Volunteer with a wrist circumference between 14.5 and 21 cm (wrist compatible with the size of the bracelet).
- Adults, having expressed their consent to research, affiliated to a social security scheme and registered in the national file of people who lend themselves to biomedical research
- Any history or presence of chronic disease.
- Volunteer presenting chronic pain and / or headache.
- Metal or silicon allergy.
- Volunteer with a piercing or an implanted metallic material on the internal face of the right wrist.
- Volunteer with a tattoo on the inside of the right wrist.
- People with contraindications to MRI.
- Taking treatment that could impact the physiological measurements recorded.
- Consumption of analgesics or anti-inflammatory drugs during the week before each MEG examination.
- Surgical intervention within the last 3 months.
- Alcohol consumption within the last 24 hours, for each visit.
- Achievement of a sporting effort within the last 24 hours, for each visit.
- Volunteer with difficulties to be cooperative during the study in the opinion of the investigator (i.e.: language problem, poor mental development, etc.).
- Volunteer in period of exclusion from another study.
- Volunteer deprived of liberty by a judicial or administrative decision, subject to psychiatric treatment, or major subject subject to a legal protection measure (guardianship, guardianship and safeguard of justice) referred to in articles 1121-6 to 1121-8 of the French public health code.
- Volunteer who would receive more than 4,500 euros in compensation as a result of his participation in other research involving the human person in the 12 months preceding this study.
- Volunteer who cannot be contacted in case of emergency.
- Volunteer who have already used an millimeter wave emitter before the study.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- CROSSOVER
- Arm && Interventions
Group Intervention Description Millimeter wave emitter status 2 Millimeter waves local exposure Somatosensory stimulus during Magnetoencephalography (MEG) records Millimeter wave emitter status 1 Millimeter waves local exposure Somatosensory stimulus during Magnetoencephalography (MEG) records
- Primary Outcome Measures
Name Time Method Change in the somatosensory responses induced by the application of millimeter waves to the wrist 4 hours Statistically significant change in the evoked somatosensory magnetic activity time course
- Secondary Outcome Measures
Name Time Method Variation of the sympathovagal balance following the application of millimeter waves 4 hours Comparison of heart rate variability before and after application of millimeter waves
Changes in resting brain activity during or after application of millimeter waves to the wrist 4 hours Characterization of oscillatory brain activity by frequency bands (power maps)
Trial Locations
- Locations (1)
Clinatec Cea/Chuga
🇫🇷Grenoble, France