Assessment of the Reproducibility of the 3 Minutes Sit-to-stand Test in Patients With Idiopathic Pulmonary Fibrosis (IPF)
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 35
- 试验地点
- 4
- 主要终点
- Reproductibility of the 3 minutes sit-to-stand test in patient with idiopathic pulmonary fibrosis
研究概览
简要总结
This study is designed to evaluate the reproductibility and the performance of the 3 minutes sit-to-stand test in patients with idiopathic pulmonary fibrosis.
To do this, the investigators are recruiting 40 patients with idiopathic pulmonary fibrosis in 2 centers (Grenoble university hospital and Lyon university hospital).
Patients had to achieve an effort test on a cycle ergometer. 2 visits are planned in the hospital. During each visit, patients will perform a 3 minutes sit-to-stand test, a 1 minute sit-to-stand test and a 6 minutes walk test. During the second visit, patients will also perform a 3 minutes sit-to-stand test with measurement of oxygen uptake.
The investigators will then analyse the results by comparing numbers of cycle, functional response and symptoms during the 3 minutes sit-to-stand test of the 2 visits. The investigators will also compare the functional response obtained during the 3 minutes sit-to-stand test, the 1 minute sit-to-stand test and the 6 minutes walk test.
Finally, the investigators will compare the maximal values of oxygen uptake, respiration rate and expired volume obtained during the 3 minutes sit-to-stand test to the effort test on cycle ergometer.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 85 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •man or woman aged less than 85 years
- •patients with Idiopathic Pulmonary Fibrosis without any acute exacerbation during 4 months before the inclusion
- •Non-opposition to participation in research
- •Patient with 6 minutes walk test > 200 meters (with or without oxygen therapy)
排除标准
- •Patient with reduced locomotor activity, or joint pain that compromises the performance of the tests
- •Patient with 6 minutes walk test < 200 meters
- •Patient with an other etiology of pulmonary fibrosis
- •Other significant pulmonary diseases
- •Patient with unstable cardiac disease
- •Patient who may be, according to the investigator's assessment, not cooperating or respecting the obligations inherent in participating to the study.
- •Opposition to participation in research
研究组 & 干预措施
patient with idiopathic pulmonary fibrosis
干预措施: 3 minutes sit-to-stand test (Diagnostic Test)
结局指标
主要结局
Reproductibility of the 3 minutes sit-to-stand test in patient with idiopathic pulmonary fibrosis
时间窗: 2 days
Evaluate the reproductibility for the number of rise and down during the 3 minutes sit-to-stand test of the 2 visits (the investigators will compare the number of rise and sit during the 3 minutes sit-to-stand test of the 2 visits to see if they are similar)
次要结局
- 1 minute sit-to-stand test compared to 3 minutes sit-to-stand: oxygen saturation(2 days)
- Functional response during the 3 minutes sit-to-stand test: Heart rate(2 days)
- Functional response during the 3 minutes sit-to-stand test: symptoms(2 days)
- 3 minutes sit-to-stand test compared to the 6 minutes walk test: symptoms(2 days)
- Functional response during the 3 minutes sit-to-stand test: Oxygen saturation(2 days)
- 3 minutes sit-to-stand test compared to the 6 minutes walk test: oxygen saturation(2 days)
- 3 minutes sit-to-stand test compared to the 6 minutes walk test: heart rate(2 days)
- 1 minute sit-to-stand test compared to 3 minutes sit-to-stand: heart rate(2 days)
- 1 minute sit-to-stand test compared to 3 minutes sit-to-stand: symptoms(2 days)
