跳至主要内容
临床试验/NCT03803969
NCT03803969已完成不适用

ConfirmRxTM: Effects of Patient Posture and Physical Activity

Abbott Medical Devices16 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2018年10月30日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
100
试验地点
16
主要终点
Characterisation of the safety and performance of Confirm Rx™ with changes in posture and physical activity at implant and 30days post procedure

研究概览

简要总结

Insertable Cardiac Monitor's (ICM's) such as Confirm Rx™ are leadless devices implanted for long-term heart rhythm monitoring in the diagnosis and management of clinical conditions such as recurrent unexplained syncope, cryptogenic stroke, ventricular arrhythmias and monitoring atrial fibrillations (AF) post ablation. There is limited data on variations seen in signal sensing with changes in physical activity and posture. This single arm, non-randomized, open-label, multi-center, clinical investigation of 100 subjects is designed to characterise the safety and performance of Confirm RxTM by assessing quality of signal attained from the device with changes in posture and physical activity at implant and 30days post procedure. The study is also intended to assess gross migrations of the device at 30days post implant.

详细描述

Syncope is a condition that has vexed cardiologists worldwide due to its elusive nature. Often a third of patients with syncope remain undiagnosed despite assessments by multidisciplinary teams and the availability of various screening techniques such as electrocardiography, 24-h Holter monitoring, carotid sinus massage, echocardiography, exercise testing, head-up tilt test, and electrophysiological studies. Recently, ICM's have been developed to continuously monitor heart rhythm and thus aid in the diagnoses and management of clinical conditions such as ventricular arrhythmias, cryptogenic stroke, recurrent unexplained syncope and for monitoring atrial fibrillations (AF) post ablation. ICM's such as Confirm Rx from Abbott are leadless devices that detect arrhythmias largely depending on sensing of changes in R-R interval and R wave amplitude in the ECG signal. Whilst ICM's have been helpful in detecting arrhythmias in up to 40% of these patients with unexplained syncope, there is paucity of data regarding changes in signal quality with variations in body posture, physical activity and device movements that could potentially have effects on ECG signal and thus event detection. To this extent, this is an Abbott sponsored prospective, single arm, non-randomized, open-label, multi-center, clinical trial of 100 subjects designed to characterize the safety and performance of Confirm Rx™ in relation to physical activity and posture in these subjects with unexplained syncope.

ConfirmRx™ has come a long way since its inception with a significant reduction in size (78% reduction by volume) that has led to relatively simple insertion procedures through a small skin incision. The less complicated insertion process permits the insertion procedure to take place in settings besides operating rooms and furthermore, smaller devices are associated with significantly lower incidence of infections. We believe that this study will add to growing body of evidence of the efficacy of ConfirmRx.

The primary objective of this clinical investigation is to characterise the safety and performance of the Confirm Rx™ Insertable Cardiac Monitor (ICM) by assessing quality of signal attained from device post implant with changes in posture and physical activity at implant and 30days post procedure.

Primary Endpoints

  • Changes in R-wave amplitudes at time of insertion and 30 days post-insertion.
  • Changes in R-wave amplitude with below defined movements at time of insertion, and 30days post-insertion.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Eligible patients will meet all the following:
  • Subjects are 18 years of age or older, or of legal age to give informed consent specific to state and national law.
  • Subject must provide written informed consent prior to any clinical investigation related procedure.
  • Have an approved indication for continuous arrhythmia monitoring with an Insertable Cardiac Monitor.
  • Should be willing and able to comply with the prescribed follow-up tests and schedule of evaluations.
  • Female subjects of child-bearing potential should have a negative pregnancy test done within 7 days prior to the index procedure per site standard test.

排除标准

  • Patients will be excluded if they meet any of the following:
  • Subject has previously received an Insertable Cardiac Monitor.
  • Subject is currently enrolled or intend to participate in another clinical investigation, which could confound the results of this trial during this clinical study as determined by the sponsor.
  • Pregnant or nursing subjects and those who plan pregnancy during the clinical investigation follow-up period.
  • Presence of other anatomic or comorbid conditions, or other medical, social, or psychological conditions that, in the investigator's opinion, could limit the subject's ability to participate in the clinical investigation or to comply with follow-up requirements, or impact the scientific soundness of the clinical investigation results.

结局指标

主要结局

Characterisation of the safety and performance of Confirm Rx™ with changes in posture and physical activity at implant and 30days post procedure

时间窗: 30+15 days post procedure

Patient performs defined movements post insertion of device and assessments are made on the Merlin Programmer. These are repeated 30+15 days post procedure

次要结局

  • Identification of any gross migration of Confirm Rx device 30 days following implant(30+15 days post procedure)

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (16)

Loading locations...

相似试验

ConfirmRxTM: Posture and Activity | 临床试验