Image Guided Adaptive Radiotherapy Based on Elastic Image Registration for Improved Tumor Coverage and Reduction of Side Effect in Normal Tissues
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 18
- 主要终点
- Planning Target Volume (PTV) Coverage Parameter D98%
研究概览
简要总结
Aim of this study is the clinical evaluation of an image-guided adaptive radiotherapy concept. This involves the adaption of the radiotherapy treatment plan according to changes in tissues and variations in patients position and posture during a radiotherapy treatment course, based on repeat CT scans.
It is investigated, if dosimetric improvements can be achieved using this approach and if the method using the software-package "ReDeform" can be implemented in clinical Routine.
详细描述
Aim of this study is the clinical evaluation of an image-guided adaptive radiotherapy (ART) concept. This involves the adaption of the radiotherapy treatment plan according to changes in tissues and variations in patients position and posture during a radiotherapy treatment course, based on repeat CT scans.
It is prospectively investigated, if dosimetric improvements can be achieved using this approach and if the method using the software-package "ReDeform" can be implemented in clinical Routine. For that purpose 2 repeat CT scans are acquired during the radiotherapy course (week 3 and week 5 of radiotherapy). The Initial CT scan is "matched" to the follow-up CT-scan by means of deformable image registration.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients with histo-pathologically verified malignancies in the head-and-neck without clinical signs of dissemination, who consented in radiotherapy or radio-chemotherapy.
排除标准
- •previous radiation therapy for head-and-neck
结局指标
主要结局
Planning Target Volume (PTV) Coverage Parameter D98%
时间窗: week 5
Dose coverage of the planning target volume: Number of participants with a decrease in the planning target volume (PTV) coverage (D98%) above 5%. The Parameter "D98%" denotes the minimum dose to 98% of the volume according to the ICRU (International Commission on Radiation Units \& Measurements) Report No. 62. It is a widely accepted classification index for dose coverage. The "Planing Target Volume" is a volume, consisting of the clinical target volume and additional safety margins, that should receive a certain radiation dose.
次要结局
- Volumetric Changes(week 5)