跳至主要内容
临床试验/NCT04708717
NCT04708717招募中不适用

Encoding Temporal Fine Structure for Cochlear Implants

University of Southern California1 个研究点 分布在 1 个国家目标入组 24 人开始时间: 2020年9月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
24
试验地点
1
主要终点
Endpoint electrode psychophysics.

研究概览

简要总结

The goal of this study is to improve music and speech perception for cochlear implant users. Presently, most cochlear implants discard the temporal fine structure of sound, which is information that is widely believed to contribute to both music and speech perception. The proposed work examines perceptual and physiological changes that occur once this information is provided to cochlear implant users in a clear and consistent manner.

详细描述

The study goal is to improve music and speech perception for cochlear implant users. The relevant health outcome is their quality of life. This proposal focuses on how well cochlear implant users can learn to use temporal fine structure if provided as a clear and consistent cue for music or voice pitch. Historically, cochlear implants have discarded temporal fine structure and have only transmitted timing information of relatively slow envelope fluctuations. Attempts have been made to restore temporal fine structure into cochlear implant stimulation, but it is unclear whether previous attempts were limited by implementation, lack of experience, or inherently by physiology. The proposed approach is unique in that it examines the perceptual and physiological plasticity that occurs when temporal fine structure is restored. Proposed research is organized into two aims, which examine the relative salience of stimulation place and rate for providing a sense of pitch (Aim 1) and the salience of dynamic-rate stimulation compared to conventional methods (Aim 2). Both aims combine perceptual learning, computer-controlled electrode psychophysics, electrophysiology, and computational neural modeling to characterize the plasticity of pitch perception in cochlear implant users.

Aim 1 examines the perceptual and physiological plasticity associated with place and rate of cochlear implant stimulation. Cochlear implant users hear an increasing pitch associated with increasing stimulation rate, but this effect is difficult to measure above 300 Hz. Most studies of psychophysical sensitivity to cochlear implant stimulation rate have not considered perceptual learning. Preliminary results show that the sense of pitch provided by stimulation rate improves with training. The proposed research examines perceptual sensitivity and physiological encoding throughout a crossover training study with training provided for pitch based on place and rate of stimulation. The primary hypothesis tested is that cochlear implant users have a latent ability to hear pitch associated with stimulation rate, but they require training to learn how to use this new information.

Aim 2 is to determine whether dynamic-rate stimulation provides better sensitivity and better physiological encoding of fundamental frequency compared to conventional stimulation methods based on amplitude modulation of constant-rate stimulation. In normal physiology, auditory-nerve activity phase locks to the temporal fine structure of sound. Since cochlear implants typically discard this information, it is unknown how well cochlear implant users can learn to use it if provided. Aim 2 focuses on the comparison between dynamic-rate stimulation in which stimulation rate is dynamically adjusted to convey temporal fine structure compared to conventional methods based on amplitude modulation of constant-rate stimulation. The primary hypothesis is that dynamic-rate stimulation provides better pitch sensitivity and better physiological encoding compared to amplitude modulation of constant-rate stimulation.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •Cochlear implant users.

排除标准

  • •Younger than 18 years.

研究组 & 干预措施

Stimulation Rate

Experimental

干预措施: Stimulation Rate (Behavioral)

Stimulation Rate

Experimental

干预措施: Electrode Location (Behavioral)

Electrode Location

Active Comparator

干预措施: Stimulation Rate (Behavioral)

Electrode Location

Active Comparator

干预措施: Electrode Location (Behavioral)

结局指标

主要结局

Endpoint electrode psychophysics.

时间窗: Measure collected at 8-week endpoint following psychophysical training.

Just-noticeable difference for pitch ranking based on stimulation cues. Pitch discrimination will be measured as provided independently by place and rate of cochlear implant stimulation, as well as in combination. Stimuli will be dual-electrode pulse trains, which probe place-pitch perception with greater resolution than possible with single-electrode stimulation. Two-alternative forced-choice procedures will be used in which participants judge which of two stimuli is higher in pitch. Frequency discrimination will be measured near condition frequencies of 110, 220, 440, 880, and 1760 Hz for each of the 4 stimulation conditions (place, rate, combined). Adaptive procedures will be used to measure 75% discrimination accuracy.

Baseline electrode psychophysics prior to training.

时间窗: Measure collected prior to training.

Just-noticeable difference for pitch ranking based on stimulation cues. Pitch discrimination will be measured as provided independently by place and rate of cochlear implant stimulation, as well as in combination. Stimuli will be dual-electrode pulse trains, which probe place-pitch perception with greater resolution than possible with single-electrode stimulation. Two-alternative forced-choice procedures will be used in which participants judge which of two stimuli is higher in pitch. Frequency discrimination will be measured near condition frequencies of 110, 220, 440, 880, and 1760 Hz for each of the 4 stimulation conditions (place, rate, combined). Adaptive procedures will be used to measure 75% discrimination accuracy.

Midpoint electrode psychophysics.

时间窗: Measure collected at 4-week midpoint during psychophysical training.

Just-noticeable difference for pitch ranking based on stimulation cues. Pitch discrimination will be measured as provided independently by place and rate of cochlear implant stimulation, as well as in combination. Stimuli will be dual-electrode pulse trains, which probe place-pitch perception with greater resolution than possible with single-electrode stimulation. Two-alternative forced-choice procedures will be used in which participants judge which of two stimuli is higher in pitch. Frequency discrimination will be measured near condition frequencies of 110, 220, 440, 880, and 1760 Hz for each of the 4 stimulation conditions (place, rate, combined). Adaptive procedures will be used to measure 75% discrimination accuracy.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Raymond Goldsworthy

Associate Professor

University of Southern California

研究点 (1)

Loading locations...

相似试验

Encoding Temporal Fine Structure for Cochlear... | 临床试验