跳至主要内容
临床试验/NCT07840339
NCT07840339已完成不适用

Evaluation of the Accuracy of Pterygoid Implant Placement Using a Custom-Made Surgical Guide for the Rehabilitation of Atrophic Posterior Maxilla

Tanta University1 个研究点 分布在 1 个国家目标入组 9 人开始时间: 2024年8月22日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
9
试验地点
1
主要终点
Accuracy of custam made surgical guide

研究概览

简要总结

The aim of this clinical study is to evaluate the accuracy of placing pterygoid implants using custom-made surgical guides in patients with atrophied posterior maxilla. The study focuses on measuring how closely the actual implant position matches the virtual preoperative plan in terms of angle and distance.

详细描述

Rehabilitation of the atrophic posterior maxilla remains a surgical challenge. This study utilizes pterygoid implants as a graftless solution. For each participant, a digital workflow is followed: a cone-beam computed tomography (CBCT) scan and an intraoral scan are performed to design a custom-made surgical guide. Following implant placement, a postoperative CBCT is obtained. The accuracy is then evaluated by superimposing the planned and actual implant positions to calculate the coronal, apical, and angular deviations.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
20 Years 至 60 Years(Adult)
性别
All
接受健康志愿者
否

入选标准

  • •The patients recruited for the study were selected according to the following criteria:
  • •The age of the patients is between 20-60 years.
  • •Partially and completely maxillary edentulous patients whose sinus pneumatization and refuse other treatment options.
  • •Bone height related to the sinus is less than 5 mm.

排除标准

  • •Prior radiation therapy
  • •Soft and hard tissue pathology at the operation site • Systemically:
  • •1. Patients with uncontrolled systemic disease
  • •Previous chemotherapy and/or antiresorptive agents
  • •Heavy smoking (e.g., two packs per day)

研究组 & 干预措施

Guided Pterygoid Implant

Experimental

Patients with atrophic posterior maxilla receiving pterygoid implants using a custom-made digital surgical guide to evaluate placement accuracy.

干预措施: 3D Printed Digital Surgical Guide (Device)

结局指标

主要结局

Accuracy of custam made surgical guide

时间窗: Immediately postoperative

Evaluation of the deviation between the virtual preoperative plan and the actual postoperative implant position. This includes angular and linear deviation

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Abdallah ahmed fathi gomaa

MSCs researcher

Tanta University

研究点 (1)

Loading locations...

相似试验