Effect of Semiconductor Embedded Therapeutic Gloves for Hand Osteoarthritis
- Conditions
- Hand OsteoarthritisOsteoarthritis
- Registration Number
- NCT06744855
- Lead Sponsor
- Altoona Center for Clinical Research
- Brief Summary
The goal of this study is to evaluate change in symptoms using semiconductor embedded gloves for hand osteoarthritis.
- Detailed Description
The semiconductor embedded fabric emits mid-level and far infrared waves and negative ions to the tissue which can increase circulation of both blood and lymph, plus facilitates the anti-inflammatory nitric oxide cascade by accelerating the binding of Calcium to Calmodulin. Nitric oxide down-regulates interleukin1 beta and inducible nitric oxide synthase in certain cell types, which leads to reduced cyclooxygenase-2 and prostaglandins-molecules responsible for causing inflammation and pain. Unlike other systemic COX-2 inhibitors such as nonsteroidal anti-inflammatory drugs (NSAIDs), targeted infrared and negative ion therapy stimulate localized reaction pathways, thereby reducing pain and inflammation. This study seeks to identify patient reported subjective and clinically measured objective outcomes for hand osteoarthritis pain management and hand function with application of semiconductor embedded fabric in the affected area.
Recruitment & Eligibility
- Status
- NOT_YET_RECRUITING
- Sex
- All
- Target Recruitment
- 140
- Patients diagnosed with erosive hand OA, non-erosive hand OA, or first carpometacarpal joint OA with a Kellgren- Lawrence grade >1 as determined by radiographic assessments and the American College of Rheumatology (ACR) classification
- Patients age 40-75
- Patients who are willing and able to adhere to follow-up schedule and protocol guidelines.
- Patients who are willing and able to sign corresponding research subject consent form.
-
Patient has a history of neurological conditions, including multiple sclerosis or Parkinson's disease
-
Patient has had prior surgical treatment of the hands in the last 5 years or injection treatment in the last 6 months
-
Patient has secondary OA including causes such as gout, rheumatoid arthritis, psoriatic arthritis
-
Patient has used topical creams or gels for arthritic pain including nonsteroidal anti-inflammatory drugs, capsaicin, lidocaine, or counterirritants in the last 1 week
-
Patient has a history of carpal tunnel syndrome, cubital tunnel syndrome, or radial tunnel syndrome
-
Patient has a history of peripheral neuropathy
-
Patient has chronic pain conditions unrelated to hand condition
-
Patient has auto-immune or auto-inflammatory diseases
-
Patient has used tobacco within the last 90 days
-
Patient is not within the ages of 40-75
-
Patient has an active infection (local or systemic)
-
Patient is unwilling or unable to sign the corresponding research subject consent form
-
Patient meets any other criteria or has any other condition that, in the opinion of the investigator, would prevent them from completing the study or that, in the opinion of the investigator, would confound study results.
Exclusion Criteria:
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Primary Outcome Measures
Name Time Method Change in pain as measured by the Visual Analog Scale (VAS) Baseline and weekly for 9 months The pain VAS is a unidimensional measure of pain intensity, used to record patients' pain progression, or compare pain severity between patients with similar conditions. The minimum number is zero meaning no pain and maximum number is 10 meaning the most pain the patient has every felt in their entire life. Lower scores are ideal while higher scores are indicative of the patient in a lot of pain.
- Secondary Outcome Measures
Name Time Method Change in patient hand function as determined by the Australian Canadian Osteoarthritis Hand Index (AUSCAN) Baseline, 3 months, 6 months, and 9 months The Australian/Canadian Osteoarthritis Hand Index (AUSCAN) is a self-administered questionnaire that assesses hand pain, stiffness, and function in patients with osteoarthritis. It is on a 5-point Likert scale, with pain severity questions and answer ranges from strongly disagree to strongly agree.
Change in patient hand function as determined by the Functional Index for Hand Osteoarthritis (FIHOA) Baseline, 3 months, 6 months, and 9 months The Functional Index for Hand Osteoarthritis (FIHOA) is a self-administered patient specific questionnaire to assess the patient's function with hand osteoarthritis. It has 10 questions and is on a 4-point Likert scale with 0 = possible without difficulty • 1 = possible with slight difficulty • 2 = possible with important difficulty • 3 = impossible.
Change in patient grip strength Baseline, 3 months, 6 months, and 9 months Patient's grip strength will be assessed with a hand dynamometer. The patient will squeeze the device with the patient's elbow at 90 degrees of flexion and wrist in 30 degrees of extension. A force output value in pounds (lbs) will be displayed and a higher number of force output indicates a stronger grip strength.
Radiographic changes as determined by hand x-rays. Baseline and 9 months Change of the arthritic hand joint health such as reduction in osteophyte formation, presence of erosions, and joint space narrowing as measured by radiographic assessments compared to pre-treatment scans. The PI will determine if the arthritic hand has improved, stabilized, or worsened during the intervention.
Related Research Topics
Explore scientific publications, clinical data analysis, treatment approaches, and expert-compiled information related to the mechanisms and outcomes of this trial. Click any topic for comprehensive research insights.
Trial Locations
- Locations (1)
Altoona Center for Clinical Research
🇺🇸Duncansville, Pennsylvania, United States
Altoona Center for Clinical Research🇺🇸Duncansville, Pennsylvania, United StatesLisa A Claycomb, Clinical Research Administrator, CRCPContact18009247790altoonaresearch@gmail.comAlan J Kivitz, MD, CPIContact