Ammonia N-13 Myocardial Blood Flow Absolute Quantification by Positron Emission Tomography in Patients With Known or Suspected Coronary Artery Disease (Ammonia MAP)

Ionetix Corporation5 个研究点 分布在 1 个国家目标入组 2,500 人开始时间: 2020年9月14日最近更新:
适应症
干预措施
相关药物

试验速览

阶段
不适用
状态
招募中
入组人数
2,500
试验地点
5
主要终点
Establish the N-13 measured MBF (ml/g/min) value range

研究概览

简要总结

This study is being conducted to provide access to and collect test data for an established nuclear medicine diagnostic imaging test called Positron Emission Tomography (PET), using a specific radioactive drug called Ammonia N-13 (Ammonia), referred to simply as an Ammonia PET scan, which is used to visualize the blood flow through the blood vessels and into the heart muscle in order to identify areas of restricted blood flow within the heart. The scanner used in this study may be a stand-alone PET scanner or a PET/CT scanner, which combines the PET scanner and a Computed Tomography (CT) scanner into a single device. Unless otherwise stated in this consent form, the term PET will be used to refer to both stand-alone PET and PET/CT scanners. While physicians have used the Ammonia PET test for many years to visualize (image) the blood flow into the heart muscle (perfusion), it is now possible to also measure the flow of blood into the heart muscle. Research studies have demonstrated clinical value in reviewing the measured blood flow values in addition to reviewing the perfusion images of blood flow into the heart muscle. Therefore, this study will establish a database of a large number of Ammonia PET measured blood flow values to serve as a future reference.

详细描述

This is a prospective, multicenter database that will be populated by sites utilizing N-13 Ammonia and sponsored by Ionetix. Each site with access to N-13 produced under an investigational new drug (IND) application will be eligible to participate. Once the site is activated, the site will enroll patients into the database that are scheduled for clinically indicated PET-MPI with N-13 (as determined by their treating physicians). PET-MPI perfusion, MBF, percent ischemia, pharmacologic stress agent, and gated left ventricular ejection fraction/function values will be collected when available, in an anonymous fashion and uploaded into the database. All patient health identifiers (PHI) will be removed prior to upload. No procedures additional to those clinically indicated will be performed for the purposes of this study.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adults ≥18 able to give informed consent.
  • Clinical indication for PET-MPI as determined by the subject's treating physician

排除标准

  • Any clinical contraindication for pharmacologic stress testing per ASNC/SNMMI/ACC myocardial perfusion imaging guidelines when stress perfusion imaging is required clinically.
  • Inability or unwilling to give informed consent
  • Pregnant subjects

研究组 & 干预措施

Individuals with confirmed or suspected cardiovascular disease

Individuals in this group will undergo myocardial perfusion imaging, utilizing Ammonia N-13 PET imaging agent. Each individual will receive two intravenous injections of Ammonia N-13 in accordance with site imaging protocol.

干预措施: Myocardial Perfusion Imaging Study (Diagnostic Test)

Individuals with confirmed or suspected cardiovascular disease

Individuals in this group will undergo myocardial perfusion imaging, utilizing Ammonia N-13 PET imaging agent. Each individual will receive two intravenous injections of Ammonia N-13 in accordance with site imaging protocol.

干预措施: AMMONIA N-13 37.5 mCi in 1 mL INTRAVENOUS INJECTION [Ammonia N 13] (Drug)

结局指标

主要结局

Establish the N-13 measured MBF (ml/g/min) value range

时间窗: an estimated average of 2 hours

Non-invasive measurements of myocardial blood flow (MBF) in milliliter/minute/gram using PET/CT or PET scanner will be compared to invasive cardiac angiography values (current gold standard). MBF values are obtained using image-derived time activity curves from the left ventricular blood and myocardial tissue regions. These values represent radiotracer exchange between the blood and the tissue over time. The rate of radiotracer uptake into the myocardial tissue provides an estimate of MBF. Processing software will then use the time-activity curves to calculate MBF at rest and at stress.

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor