Skip to main content
Clinical Trials/NCT04526964
NCT04526964
Completed
Not Applicable

Improved Health Care for People With Chronic Heart Disease and Implanted Cardiac Support Through Curricular Self-management - Phase 3: Randomized Controlled Trial (RCT)

University of Freiburg4 sites in 1 country140 target enrollmentSeptember 7, 2020

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Ventricular Assist Device
Sponsor
University of Freiburg
Enrollment
140
Locations
4
Primary Endpoint
Change in Self-management Skills from 2-4 Weeks Post-implant (T1) to 12 Months Post-implant (T3)
Status
Completed
Last Updated
2 years ago

Overview

Brief Summary

The number of patients suffering from end-stage heart disease challenges healthcare services in the western world, where an estimated 1-2% of the population suffer from this chronic condition. Ventricular assist device (VAD) implantations have become a common therapeutic strategy for those affected. Live with a VAD, however, is far from normal and does expose patients to multiple challenges and the need to adjust to a complex self-management. Inadequate self-management can lead to serious complications, specifically neuro-cognitive events, bleeding, and exit-site related wound infections may impair the outcome following the VAD implantation procedure.

Based on systematized literature review and a previous prevalence assessment study (ClinicalTrials.gov Identifier: NCT04234230), a modular evidence-based curriculum has been developed by a multiprofessional group of experts. This curriculum aims at improving knowledge, skills, and competencies for those affected to empower VAD patients to better self-manage their everyday life with the VAD, and to regain quality of life. This study focuses on a multi-center implementation and evaluation of the curriculum using a fully powered randomized-controlled study (RCT) design. This RCT will be conducted at four established cardiac centers throughout Germany. Participants will be assigned to either intervention or control using a 1: 1 randomization scheme. Block-randomization will be performed by a professional from the study coordinating center not being involved into the clinical care for patients. At the participating sites, the group assignment is non-blinded to the professionals involved in order to enable the intervention so be carried out adequately. Participants in the control group (CGr) receive the standard follow-up procedures (care as usual). Participants in the intervention group (IGr) receive self-management support and skills training based on the modular self-management curriculum post-implant, and during regular outpatient follow-up. The intervention lasts for 3 months followed by a 9-month follow-up per participant. Based on the power calculations the inclusion of 142 patients is anticipated.

Detailed Description

The number of patients suffering from end-stage heart disease challenges healthcare services in the western world, where an estimated 1-2% of the population suffer from this chronic condition. Ventricular assist device (VAD) implantations have become a common therapeutic strategy for those affected. Indications include a multi-year bridging therapy (up to 10 years) and increasingly a destination therapy. The Euromacs Registry published the second report in 2018 and reported 2,947 registered VAD implantations in 2016 (+257 percent). Euromacs further points to a rising trend and demand for the use of VAD systems for the treatment of patients with end-stage failure (NYHA classes III and IV). In Germany, an increase of VAD implantation by 36.6 percent has been reported since 2011. The position paper of the German Society of Cardiology (2016) warns that the range of indications for VAD implantation for people with chronic heart disease will continue to change. The ISHLT Guideline (International Society for Heart and Lung Transplantation), published in 2018, calls for psychosocial care and standardized self-management skills of patients before, during and in the long-term after VAD implantation. This is currently being implemented inconsistently in terms of structure and quality in German cardiac centers. Live with a VAD, however, is far from normal and does expose patients to multiple challenges and the need to adjust to a complex self-management. Inadequate self-management can lead to serious complications, specifically neuro-cognitive events, bleeding, and exit-site related wound infections may impair the outcome following the VAD implantation procedure. The design for this study will be a fully-powered block-randomized trial (RCT). This RCT will be conducted at four established cardiac centers throughout Germany. Participants will be assigned to either intervention or control using a 1: 1 randomization scheme. Block-randomization will be performed by a professional from the study coordinating center not being involved into the clinical care for patients. At the participating sites, the group assignment is non-blinded to the professionals involved in order to enable the intervention so be carried out adequately. Participants in the control group (CGr) receive the standard follow-up procedures (care as usual). Participants in the intervention group (IGr) receive self-management support and skills training based on the modular self-management curriculum post-implant, and during regular outpatient follow-up. The self-management training program will be supplemented by a smartphone-based application. The smartphone application will be downloaded optionally on the patients' own smartphones, and patients will be instructed on how to use it. In the app, the study participants can receive additional information on health-related data, e.g. weight, temperature, sleep or mood. Entering health related data is absolutely voluntary. No data will be transferred to the clinical sites. The study participants can also use the app to read VAD related information only without any registration. Data entered (optional) are used only for the participants' own information overview. The intervention lasts for 3 months followed by a 9-month follow-up period per participant. Based on the power calculations the inclusion of 142 patients is anticipated. The expected results can improve self-management, self-efficacy, and health-related quality of life for patients on VAD support. In addition, a reduction in VAD-specific complications and inpatient admission rates due to reduced complication rates can expected. The project aims to improve long-term psychosocial care through self-management support for patients on VAD support. The modular curriculum and the supporting

Registry
clinicaltrials.gov
Start Date
September 7, 2020
End Date
January 15, 2023
Last Updated
2 years ago
Study Type
Interventional
Study Design
Parallel
Sex
All

Investigators

Responsible Party
Principal Investigator
Principal Investigator

Christiane Kugler

Professor Doctor. rer. biol. hum.

University of Freiburg

Eligibility Criteria

Inclusion Criteria

  • Stable postoperative condition
  • Outpatient treatment at the respective heart center
  • 18 years and older
  • No contraindications (e.g. Cognitive, Language)
  • Signed Informed Consent

Exclusion Criteria

  • Not an outpatient at the respective heart center
  • Contraindications (e.g. Cognitive, Language)
  • No signed Informed Consent
  • Participation in other behavior-related studies

Outcomes

Primary Outcomes

Change in Self-management Skills from 2-4 Weeks Post-implant (T1) to 12 Months Post-implant (T3)

Time Frame: From 2-4 weeks post-implant to 12 months post-implant

Self-managment skills and needs of the participants (for example medication intake or infection prevention) measured with a self-assessment questionnaire ("SELMA questionnaire").

Secondary Outcomes

  • Change in Perceived Social Support From 2-4 Weeks Post-implant (T1) to 12 Months Post-implant (T3)(From 2-4 weeks post-implant to 12 months post-implant)
  • Change in Symptoms of Depression From 2-4 Days Post-implant (T0) to 12 Months Post-implant (T3)(From 2-4 days post-implant to 12 months post-implant)
  • Change in Adverse Event Rates From 2-4 Days Post-implant (T0) to 12 Months Post-implant (T3)(From 2-4 days post-implant to 12 months post-implant)
  • Change in Health-related Quality of Life From 2-4 Days Post-implant (T0) to 12 Months Post-implant (T3)(From 2-4 days post-implant to 12 months post-implant)
  • Change in Symptoms of Anxiety From 2-4 Days Post-implant (T0) to 12 Months Post-implant (T3)(From 2-4 days post-implant to 12 months post-implant)

Study Sites (4)

Loading locations...

Similar Trials