跳至主要内容
临床试验/NCT07106177
NCT07106177已完成不适用

Three-dimensional Accuracy of Direct Digital Scanning for All on Four Implants in Comparison to a Custom-made Verification Jig in Fully Edentulous Patients

Yasser Ahmed1 个研究点 分布在 1 个国家目标入组 22 人开始时间: 2024年6月3日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
22
试验地点
1
主要终点
Vertical Deviation

研究概览

简要总结

The aim of this study is to assess the three-dimensional accuracy of direct intraoral scanning in All-on-4 implant-supported prostheses by comparing intraoral scan data with a custom-made verification jig.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

性别
All
接受健康志愿者
否

入选标准

  • •Patients with complete mandibular edentulism.
  • •Patients requiring full-arch rehabilitation with an All-on-4 implant concept.
  • •Absence of systemic conditions that could affect bone healing or osseointegration.
  • •Adequate bone volume in the anterior mandible for implant placement without the need for additional grafting.
  • •Patients capable of maintaining oral hygiene

排除标准

  • •Patients with uncontrolled systemic diseases (e.g., diabetes, osteoporosis).
  • •History of head and neck radiation therapy.
  • •Severe parafunctional habits (e.g., bruxism).
  • •Patients with inadequate bone volume requiring extensive grafting procedures.
  • •Active periodontal or oral infections.

研究组 & 干预措施

Scanning with the aid of jig

Experimental

干预措施: Scanning with verification jig (Other)

Scanning without jig

Active Comparator

干预措施: Direct intraoral scanning (Other)

结局指标

主要结局

Vertical Deviation

时间窗: through study completion, an average of 1 year

Analogues Saved from the Intraoral scan and those saved from stone model were superimposed. The vertical discrepancy (mm) in implant position between intraoral digital scanning and verification jig-based stone model in All-on-4 implant cases.

Angular deviation

时间窗: through study completion, an average of 1 year

Analogues Saved from the Intraoral scan and those saved from stone model were superimposed. The angular difference (degrees) in implant position between intraoral digital scanning and verification jig-based stone model in All-on-4 implant cases.

Horizontal deviation

时间窗: through study completion, an average of 1 year

Analogues Saved from the Intraoral scan and those saved from stone model were superimposed. The horizontal discrepancy (mm) in implant position between intraoral digital scanning and verification jig-based stone model in All-on-4 implant cases.

次要结局

未报告次要终点

研究者

发起方
Yasser Ahmed
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Yasser Ahmed

Associate Professor of Fixed Prosthodontics

Alexandria University

研究点 (1)

Loading locations...