CP1150 Sound Processor Speech Perception Compared With the Next Generation of Signal Processing Technology
- Conditions
- Hearing Impairment, Sensorineural
- Interventions
- Device: CP1150 Sound ProcessorDevice: CP1150 NFDevice: CP1150 + FFDevice: CP1110
- Registration Number
- NCT05286385
- Lead Sponsor
- Cochlear
- Brief Summary
This clinical study aims to investigate speech performance in quiet with an OTE Sound Processor with modified firmware compared with the commercially available CP1150. The study also investigates CP1110 and CP1150 with Forward Focus.
- Detailed Description
This study will build on the evidence previously collected on OTE and BTE Sound Processors and will support the design goals for access to the same sound processing algorithms across future OTE and BTE variants, including evidence required on the automation of FF and future implant compatibility.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 10
- Aged 18 years or older
- Post lingually deafened
- Implanted with the CI600 Series, CI500 Series or Freedom Series
- At least 6 months experience with a cochlear implant.
- At least 3 months experience with a CP910/920, CP950, CP1150, or CP1000 Sound Processor
- MAP Total Stimulation Rate of 7.2kHz or greater
- Able to score 30% or more with CI alone on a monosyllabic words in quiet test
- Willingness to participate in and to comply with all requirements of the protocol
- Fluent speaker in English as determined by the investigator
- Willing and able to provide written informed consent
- Additional disabilities that would prevent participation in evaluations.
- Implant location that would result in undesirable hearing performance or discomfort with an off-the-ear sound processor, as determined by the investigator.
- Unable or unwilling to comply with the requirements of the clinical investigation, as determined by the Investigator.
- Investigator site personnel directly affiliated with this study and/or their immediate families; immediate family is defined as a spouse, parent, child, or sibling.
- Cochlear employees or employees of Contract Research Organisations or contractors engaged by Cochlear for the purposes of this investigation.
- Currently participating or participated in another interventional clinical study/trial in the past 30 days unless (if less than 30 days) the prior investigation was Cochlear sponsored and determined by the investigator to not impact clinical findings of this investigation.
- Implanted with other active implantable medical devices (e.g. pacemaker, defibrillator).
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- CROSSOVER
- Arm && Interventions
Group Intervention Description Test Order 2 CP1110 CP1150 NF, then CP1150 + FF, then CP1150, then CP1110 Test Order 3 CP1110 CP1150 + FF, then CP1110, then CP1150 NF, then CP1150 Test Order 3 CP1150 NF CP1150 + FF, then CP1110, then CP1150 NF, then CP1150 Test Order 2 CP1150 NF CP1150 NF, then CP1150 + FF, then CP1150, then CP1110 Test Order 2 CP1150 + FF CP1150 NF, then CP1150 + FF, then CP1150, then CP1110 Test Order 1 CP1150 NF CP1150, then CP1150 NF, then CP1110, then CP1150 + FF Test Order 1 CP1150 + FF CP1150, then CP1150 NF, then CP1110, then CP1150 + FF Test Order 4 CP1150 Sound Processor CP1110, thenCP1150, then CP1150 + FF, then CP1150 NF Test Order 1 CP1150 Sound Processor CP1150, then CP1150 NF, then CP1110, then CP1150 + FF Test Order 3 CP1150 + FF CP1150 + FF, then CP1110, then CP1150 NF, then CP1150 Test Order 4 CP1150 NF CP1110, thenCP1150, then CP1150 + FF, then CP1150 NF Test Order 2 CP1150 Sound Processor CP1150 NF, then CP1150 + FF, then CP1150, then CP1110 Test Order 1 CP1110 CP1150, then CP1150 NF, then CP1110, then CP1150 + FF Test Order 3 CP1150 Sound Processor CP1150 + FF, then CP1110, then CP1150 NF, then CP1150 Test Order 4 CP1110 CP1110, thenCP1150, then CP1150 + FF, then CP1150 NF Test Order 4 CP1150 + FF CP1110, thenCP1150, then CP1150 + FF, then CP1150 NF
- Primary Outcome Measures
Name Time Method Speech Perception in Quiet Using an CP1150 Sound Processor One day (in booth testing) Paired difference in percentage CNC Words correct in quiet with the CP1150 Sound Processor and CP1150 Sound Processor with modified firmware.
- Secondary Outcome Measures
Name Time Method Speech Perception in Quiet With CP1150 and CP1110 Sound Processors One day (in booth testing) Paired difference in percentage CNC Words correct in quiet with the CP1150 Sound Processor and CP1110 Sound Processor
Speech Perception in Quiet Using CP1150 Sound Processor Using Forward Focus Combined With Standard Microphone Directionality. One day (in booth testing) Paired difference in percentage CNC Words correct in quiet with the CP1150 Sound Processor and CP1150 Sound Processor with forward focus
Trial Locations
- Locations (1)
Cochlear Sydney
🇦🇺Macquarie Park, New South Wales, Australia