Prostate Localization During Radiotherapy Using a Ni-Ti Stent and Electronic Portal Imaging - Protocol II

Aalborg University Hospital2 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2006年1月最近更新:
适应症

试验速览

阶段
1 期
状态
已完成
入组人数
100
试验地点
2
主要终点
stent in situ during radiotherapy

研究概览

简要总结

A new method for localization of the prostate during external beam radiotherapy. The method is based on insertion of a new thermo-expandable Ni-Ti stent. The radiological properties of the stent are used for precise prostate localization during treatment using electronic portal images

详细描述

Inclusion criteria's in the study were 1) Patients should present with histological verified local or locally advanced PC (stage T2b to T3b, N0, M0; UICC 1992 classification was used). 2) Patients should consequently be candidates for intended curative radiotherapy. Prostatic work up is done before inclusion in the study. A new prostatic Nickel - Titanium stent is placed in the prostatic urethra one week prior to the radiotherapy planning CT using a flexible cystoscope to insert the stent under urethral anaesthesia. The stent is then flushed with hot water (60 degrees Celsius). The hot water expands the stent collar, thereby locking the stent in place. Correct positioning of the stent is secured visually on retraction of the scope. Radiotherapy of prostate is given to a mean dose of 70 (department standard regime). Treatment are given with daily fractions of 2 Gy using a combination of 6 MV and 18 MV X-ray fields using isocentric 3D conformal treatment plan, consisting of three MLC conformal radiation fields (One anterior and two lateral wedged fields). This was assumed to be the optimal treatment plan. A pair of orthogonal 15 cm x 15 cm isocenter setup fields was added to the plan. The orthogonal fields are used to obtain pairs of electronic portal images. Electronic portal images are recorded using a Varian As500 electronic portal imaging device (EPID). The images are used to determine the 3D reference position of the stent. The image pairs of the stent were taken at eight treatment sessions in each patient (Session number 1,2,3,6,11,21,22 and 23). From each orthogonal set of images the 3D position of both the stent and the symphysis (pubic bone) are determined. Positions are calculated using orthogonal reconstruction. A control CT scan is made before treatment session number 21 to verify the intra prostatic position of the stent. The intra prostatic position of the stent is also verified during removal of the stent three months after radiation therapy. Before removal the stent was flushed with water at 10 degrees Celsius. When cooled with 10°C cold water, the stent became super soft, and can easily be removed as a twisted wire.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

性别
Male
接受健康志愿者

入选标准

  • Patients should present with histological verified local or locally advanced PC (stage T2b to T3b, N0, M0; UICC 1992 classification was used).
  • Patients should consequently be candidates for intended curative radiotherapy -

排除标准

  • dislocation or removal of stent

结局指标

主要结局

stent in situ during radiotherapy

时间窗: 8 weeks

次要结局