Skip to main content
Clinical Trials/NCT03946761
NCT03946761WithdrawnNot Applicable

Evaluation of Fluorescence Imaging in Hepatobiliary Surgery

Washington University School of Medicine0 sitesStarted: December 31, 2021Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Withdrawn
Primary Endpoint
The minimum dose of the ICG that causes initial fluorescence of the liver

Study Overview

Brief Summary

A current gap in the use indocyanine green fluorescence to isolate the biliary system is the dosing amount necessary to fluoresce the biliary system without "over" fluorescing the liver and gallbladder. Over fluorescing surrounding structures such as the liver and gallbladder saturates the image and makes it impossible to identify biliary leaks or differentiate branches of the common bile duct using fluorescent imaging devices. The over dosing does not affect the standard of care procedure, but eliminates the added benefit of the fluorescent imaging technology. The use of "microdoses" (approximately 0.1 mg) of indocyanine green has been trialed and shown promise in some patients. This study aims to do an in depth study utilizing the Cancer goggle systems fluorescent imaging system to determine the correct dose needed to isolate the biliary system without over fluorescing surrounding structures. This dosing study could additionally serve as a pilot study for follow on research using indocyanine green and fluorescent imaging in hepatobiliary surgery.

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Diagnostic
Masking
None

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • •Planned open liver resection or ablation.
  • •At least 18 years of age.
  • •Able to understand and willing to sign a written informed consent document.

Exclusion Criteria

  • •History of allergic reactions attributed to ICG, iodine, iodine dye, or other agents used in the study.

Arms & Interventions

Cancer goggle system

Experimental
  • The surgical procedure will be performed according to standard practice, with the exception of microdosing of ICG & visualization of biliary/liver anatomy using the cancer goggles system
  • The surgeon will start with a peripherally injected microdose of 0.02 mg of ICG & will inject an additional 0.02mg every 5 minutes until a noticeable fluorescent change in the liver is observed. If a change is not observed after 0.14 mg has been injected then the microdosing regimen will stop. Output video from the cancer goggles will be recorded and saved for post-surgical analysis.
  • Following resection of the liver parenchyma, the portal area and the cut surface of the liver will be analyzed for the identification of bile ducts leaks with or without cancer goggles.

Intervention: Cancer goggle system (Device)

Outcomes

Primary Outcomes

The minimum dose of the ICG that causes initial fluorescence of the liver

Time Frame: Through completion of surgery for all participants enrolled (estimated to take 1 year)

Secondary Outcomes

  • The visible status of the bile ducts and/or bile leaks from the cut surface of the liver at ICG doses administered in our dosing regimen(Through completion of surgery for all participants enrolled (estimated to take 1 year))

Investigators

Sponsor Class
Other
Responsible Party
Sponsor

Similar Trials