Early Results of ULD CT-scan for Extremity in Emergency Room

Centre Hospitalier Universitaire de Nīmes1 个研究点 分布在 1 个国家目标入组 70 人开始时间: 2018年2月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
70
试验地点
1
主要终点
presence or not of fracture

研究概览

简要总结

extremity trauma is a frequent reason for emergency room visits. There is an increase in the use of CT scanners in extremity trauma, due to a greater sensitivity of detection than X-rays, particularly for "occult fractures" and for the organization of treatment, particularly surgical treatment. As the number of CT scans increases, the reduction of the delivered dose has become a subject of interest.

Among the many methods used, the use of iterative reconstruction has enabled a substantial reduction in the delivered dose without compromising image quality: low-dose and ultra-low-dose protocols (effective dose equivalent to the effective dose of the Diagnostic Reference Levels of radiographs from the same region of interest) have been developped, but have not yet been evaluated in extremity trauma.

The subject of our feasibility study is to evaluate the diagnostic performance of ultra-low dose CT compared to radiographs in patients consulting for extremity trauma in the emergency room.

The recent implementation in our department of a scanner dedicated to low-dose explorations as well as the optimization of protocols has allowed the realization of ultra-low-dose scans since June 2017.

详细描述

The study included all consecutive adult patients who consulted for trauma to the extremities, i.e. hands and wrists, feet and ankles, in the emergency department between February and August 2018. Patients included had undergone digital radiography and ULD-CT for a diagnosis of trauma during weekdays, during working hours (9am-6pm), excluding weekends and holidays. Patients with severe polytrauma requiring a whole body CT scan and patients for whom digital radiography was not the first imaging modality performed were not included in the study.

ULD-CT images were acquired using a Somatom Definition AS+ CT-scan (Siemens Healthineers). Acquisition parameters were as follows: beam collimation of 64×0.6 mm; field of view of 500 mm; pitch factor of 0.85; rotation time of 1.0 s. The tube voltage was fixed at 80 kVp, and the tube current was set at 12 mAs for hands and wrists and at 15 mAs for feet and ankles. Both the automatic adjustment of tube voltage (CARE kV) and the automatic tube current modulation (CARE Dose4D) were disabled. The images were reconstructed in transverse plane of 1-mm thickness and 0.7mm overlapping, and raw data were reconstructed using the level 4 of the SAFIRE® (Sinogram Affirmed Iterative Reconstruction) algorithm. The reconstruction kernels used were "moderately smooth" (I30f) for soft tissue exploration and "strongly sharp" (I70f) for bone exploration for all locations.

Imaging interpretation Image analysis and interpretation were performed retrospectively in a blinded manner by two radiologists, a junior reader with a 3-year experience (TA, reader 1) and a senior reader with a 11-year experience (FS, reader 2). The two radiologists separately analyzed all radiographs after image anonymization and randomization of the reading rank. To limit interpretation biases, a period of 4 weeks was observed before interpretation of the ULD-CT images. They were analyzed separately by the two same radiologists, in the same blinded manner than radiographs, also after randomization of the reading rank. The images were visualized on GE Healthcare Centricity Picture Archiving and Communication System (PACS); all ULD-CT images were read in multiplanar 3-mm reconstructed slices.

研究设计

研究类型
Observational
观察模型
Other
时间视角
Retrospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Major patients consulting in the emergency room of the Nîmes University Hospital during working hours
  • Extremity Trauma: Hands/wrists Feet/ankles

排除标准

  • opposition to trial participation
  • Minor patients
  • Polytraumatized patient with body scanner considered

结局指标

主要结局

presence or not of fracture

时间窗: 1 year

number of fractures detected after consensus interpretation of the two readers

次要结局

未报告次要终点

研究者

发起方
Centre Hospitalier Universitaire de Nīmes
申办方类型
Other
责任方
Principal Investigator
主要研究者

Ahmed Larbi

hospital practitioner

Centre Hospitalier Universitaire de Nīmes