MedPath

Carry-over Effects of Repetitively Applied Transcutaneous Spinal Cord Stimulation on Spasticity

Not Applicable
Withdrawn
Conditions
Spinal Cord Injuries
Spasticity, Muscle
Interventions
Device: Stimulette r2x+
Registration Number
NCT03815721
Lead Sponsor
Swiss Paraplegic Research, Nottwil
Brief Summary

Spinal cord injury is a devastating condition, causing substantial impairment of vital body functions caudal to the lesion. A major cause of disability stems from spasticity, a common secondary sequelae. Its various clinical manifestations include spasms, clonus, and resistance to passive movements, and often present a major hindrance in rehabilitation, further deteriorate residual motor performance, and negatively impact independence and quality of life. Despite its high prevalence, successful management of spasticity has remained difficult. Standard-of-care treatment modalities are often insufficient or bear the risk of undesirable side effects further accentuating paresis. Epidural stimulation of the lumbar spinal cord via implanted electrodes provides for an alternative approach. It works through modifying the dysregulated neural signal processing of spared spinal circuitry caudal to the injury. Its ameliorative effects on severe lower-limb spasticity have been repetitively reported. Yet, epidural spinal cord stimulation in motor disorders is still off-label, applied in relatively few patients only, also because of its invasive character, the time consuming testing phase for its effective application, and the lack of markers to identify responders in advance. With the development of transcutaneous spinal cord stimulation, a method became available to activate the same input structures to the lumbar spinal cord as with epidural stimulation and hence to induce similar neuromodulatory effects, yet non-invasively, using standard equipment available at rehabilitation centers. A recent proof-of-concept study has shown that a single 30-minute session of transcutaneous spinal cord stimulation controlled various clinical signs of spasticity and augmented residual motor control in spinal cord injured individuals for several hours beyond its application. Further, in one subject, the stimulation was repetitively applied for six weeks, resulting in cumulative therapeutic effects persisting for 10 days after its discontinuation. These observations strongly suggest that the stimulation can induce beneficial neuroplastic adaptations of spared spinal systems and their interaction with residual supraspinal control. The proposed research aims at studying the reproducibility of these findings in a statistically sound cohort of individuals with spinal cord injury and testing the applicability and acceptance of transcutaneous spinal cord stimulation as a home-based therapy.

Detailed Description

Not available

Recruitment & Eligibility

Status
WITHDRAWN
Sex
All
Target Recruitment
Not specified
Inclusion Criteria
  • motor and sensory incomplete spinal cord injury classified as grade C or D on the American Spinal Injury Association Impairment Scale
  • neurological level of spinal cord injury: third cervical to tenth thoracic segment
  • chronic condition (≥ 12 months post-spinal cord injury)
  • preserved segmental and cutaneo-muscular reflexes in the lower limbs
  • able to be verticalized for 6 minutes (with walking aids)
  • preserved joint mobility, no musculoskeletal diseases
  • spasticity (with/without antispasticity medication)
  • stable antispasmodic medication one month prior to as well as during study participation
Exclusion Criteria
  • neuromuscular diseases, e.g., amyotrophic lateral sclerosis (ALS), Parkinson's disease, Guillain-Barré syndrome, muscular dystrophy
  • dermatological issues at the stimulation site
  • acute urinary tract infection at study entry
  • active implants (e.g., cardiac pacemaker, drug pump)
  • passive implants between the ninth thoracic level and the first lumbal level (e.g. metal screws/plates for surgical stabilization of spinal fractures)
  • malignant diseases
  • heart insufficiency
  • potential pregnancy (pregnancy test to be conducted as part of the first evaluation)

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
stimulation every other dayStimulette r2x+30-minute sessions of transcutaneous spinal cord stimulation using the Stimulette r2x+ will be repetitively applied 3 times per week.
daily stimulationStimulette r2x+30-minute sessions of transcutaneous spinal cord stimulation using the Stimulette r2x+ will be repetitively applied 7 times per week.
Primary Outcome Measures
NameTimeMethod
Change in spasticity indexfrom day 1 to day 57

Spasticity index based on the Wartenberg pendulum test: For the pendulum test, subjects will be in a supported sitting position with the trunk reclined approximately 30°. The examiner will lift one leg to a horizontal position, release it, and let it oscillate passively until it stops. The pendulum test will be repeated three times on each side, separated by phases of relaxation. The spasticity index is calculated subtracting the knee angle of the initial horizontal leg position from the peak flexion angle of the first swing divided by the final knee resting angle. Scores ≥ 1 denote non-spastic conditions, and 0 extreme spasticity.

Secondary Outcome Measures
NameTimeMethod
Change in numeric rating scale spasticityday 1, 8, 29, 50 and 57

The severity of spasticity is rated using a numeric rating scale from a minimum of 0 to a maximum of 10. Higher values represent worse outcome.

Change in 6-minute walk testfrom day 1 to day 57

distance in meters walked over a span of 6 minutes

Change in Penn Spasm Frequency Scalefrom day 1 to day 57

5-point scale rating the frequency and severity of spasms (0: no spasms - 4: more than 10 spasms per hour). Higher values represent worse outcome.

Change in Modified Ashworth Scalefrom day 1 to day 57

The resistance to passive movement will be clinically graded according to the Modified Ashworth Scale. Individual scores from both legs will be summed (with a value of 1.5 for the 1+ scoring category) to result in a single Modified Ashworth Scale-sum score (0-96; 0, no increase in muscle tone) per assessment. Higher values represent worse outcome.

Change in adductor tone ratingfrom day 1 to day 57

5-point ordinal scale describing adductor tone during passive abduction (0: normal tone - 4: maximal tone). Higher values represent worse outcome.

Change in resistance of the lower limbsfrom day 1 to day 57

Measure of the resistance of the lower limbs to manipulation performed by a robotic system (MotionMaker, SWORTEC SA). The MotionMaker measures torque (N) and power output (W).

Change in Walking Index for Spinal Cord Injury II Scalefrom day 1 to day 57

21-point ordinal scale that rates the extent and nature of assistance (e.g., walker, crutches, cane, braces, physical assistance) required to complete the 10-m walk test (0: unable to complete the test - 20: ambulated without any assistance). Higher values represent better outcome.

Trial Locations

Locations (1)

Swiss Paraplegic Centre

🇨🇭

Nottwil, LU, Switzerland

© Copyright 2025. All Rights Reserved by MedPath