Improving Albuminuria Screening Compliance Using a Smartphone Urinalysis Kit in the Hypertensive Non-Diabetic Population
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 999
- 试验地点
- 1
- 主要终点
- Completion of albuminuria screening
研究概览
简要总结
This study will test the effectiveness of mailed, smartphone urinalysis kits to improve albuminuria screening compliance and detection of albuminuria.
详细描述
This proposal will examine the effect of mailed, smartphone urinalysis kits to improve albuminuria screening compliance and detection of albuminuria. The investigators will randomize 1,000 non-diabetic MyGeisinger portal users with hypertension and last clinic blood pressure >= 130/80 mmHg who have not received albuminuria screening to either: 1) control - usual care or 2) intervention - mailed urinalysis smartphone kit. All patients will first receive a reminder letter to have albuminuria screening completed at their clinic in coordination with the Geisinger Care Gap Team. Patients randomized to the intervention arm who do not complete this initial screening test will then be offered a mailed, smartphone urinalysis testing kit. Patients with 1+ or greater detected urine protein will be recommended to have urine albumin/creatinine ratio (ACR) testing to confirm albuminuria. Patients with ACR >= 30 mg/g will be referred to pharmacists for optimal treatment of albuminuria (ACE or ARB, statin, BP goal <130/90 mmHg).
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Screening
- 盲法
- Single (Outcomes Assessor)
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •18 and older
- •Hypertension
- •Last outpatient BP ≥ 130/80 mmHg
- •Active MyGeisinger users with a listed mobile phone number
- •Has a Geisinger PCP and followed by the Care Gaps team
- •No prior urine albuminuria test (urine dipstick, albumin/creatinine ratio, protein/creatinine ratio)
排除标准
- •History of diabetes
- •Receiving dialysis
- •History of kidney transplant
- •eGFR < 15 ml/min/1.73m2
- •Principal investigator or PCP discretion (i.e. concerns about safety, compliance)
研究组 & 干预措施
Control - usual care
This arm will receive usual care.
Mailed Urinalysis Smartphone Kit
This arm will receive a mailed urinalysis smartphone kit if they do not complete albuminuria screening after the initial reminder to do so.
干预措施: Mailed Urinalysis Smartphone Kit (Other)
结局指标
主要结局
Completion of albuminuria screening
时间窗: Baseline to 3 months of enrollment date
Includes completion of mailed smartphone urinalysis and clinical labs (urinalysis, albumin/creatinine ratio, or protein/creatinine ratio)
Total number of detected albuminuria cases
时间窗: Baseline to 3 months of enrollment date
confirmed by urine albumin/creatinine ratio \>= 30 mg/g
次要结局
未报告次要终点
研究者
Alexander Chang
Assistant Professor
Geisinger Clinic
