跳至主要内容
临床试验/NCT00620906
NCT00620906已完成不适用

Motion Capture Analysis of Sacroiliac Joint Motion After Manipulation

Logan College of Chiropractic2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2007年1月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
20
试验地点
2
主要终点
Sacroiliac joint motion was assessed with the Polhemus Liberty motion capture system.

研究概览

简要总结

The purpose of this study is to examine the effects of manipulation on sacroiliac joint motion using a Polhemus motion capture system.

详细描述

The Sacroiliac (SI) joint is a diarthrodial joint with the contradictory biomechanical function of transmitting compressive loads from the lumbar spine to the lower extremity while maintaining a nutating motion in the pelvis.

Recent studies identify the Sacroiliac (SI) joints as a significant source of pain in patients with chronic low back pain, contributing up to 27%. Recent studies have demonstrated that historical and physical examination findings and radiological imaging alone are insufficient to diagnose SI joint pain.

The purpose of this study is to examine the effects of manipulation on sacroiliac joint motion using a Polhemus motion capture system. The Absolute angular deviation of sacroiliac joint motion will be assessed during the normal gait cycle with the Polhemus Liberty motion capture system. Six sensors will be attached to specific anatomical landmarks of the pelvis which recorded motion characteristics while walking on a treadmill at 5 mph. The subjects then receive a HVLA manipulation to the SI joint and were retested at the same treadmill speed.

The Motion capture system tracks objects at a speed of 240 updates per second on all sensors simultaneously. The latency of data sampling is less than 4ms; 240 x 60 sec x 8 Sensors totaling 115,200 data points per minute. The system generates and tracks electromagnetic fields (EMF), computes position and orientation of sensors in an X, Y, and Z coordinate system while interfacing with a computer. The EMF source contains electromagnetic coils that emit a magnetic field. The source is the system's reference frame for sensor measurements. The sensor contains electromagnetic coils (accelerometers) that detect the position and orientation of the magnetic fields emitted by the EMF source.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
20 Years 至 40 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Ages between 20 and 40
  • Ability to maintain normal balance
  • Willingness to undergo HVLA manipulation to the SI Joints
  • Normal blood pressure

排除标准

  • Any visual or vestibular condition or systemic illness that would affect balance
  • Any recent surgery, unstable joints of the lower extremity, recent hip and knee joint replacements or fitted hip or knee pins, bolts and/or plates
  • Currently have any infection, acute inflammation, recent wounds, injury, tumors or other malignancy
  • Currently taking any medications; prescription or herbal muscle stimulants, relaxants, etc.
  • A history of acute disc herniation, discopathy or spondylolysis
  • A history of acute thrombosis, serious cardiovascular disease, diabetes, have irregular heartbeats(arrhythmia) or wear a pacemaker
  • Any implanted device or prosthesis type of device
  • Any Spinal manipulation within 48 hours
  • Ages under 20 and over 40
  • Estimated BMI greater than 30

结局指标

主要结局

Sacroiliac joint motion was assessed with the Polhemus Liberty motion capture system.

时间窗: Pre and Post therapy

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Dennis Enix, DC, MBA

Assistant Professor

Logan College of Chiropractic

研究点 (2)

Loading locations...

相似试验