Analysis of Retinal Vessel Pulsations With Electrocardiographic Gating
- Conditions
- Vessels; Anomaly
- Interventions
- Device: Retinal Vessel Analyzer recordings with electrocardiographic (ECG) gating
- Registration Number
- NCT04709809
- Lead Sponsor
- University Hospital, Basel, Switzerland
- Brief Summary
Analysis of Retinal Vessel Analyzer (RVA) recordings of retinal vessel pulsations, and putting them in context of intraocular pressure (IOP) pulsations by means of electrocardiographic (ECG) gating, in order to determine the lead source for pulsations of retinal veins.
- Detailed Description
Rationale / Objective is to construct the retinal vessels wall pulsation cycle using an electrocardiographic gating, and to analyse it in comparison with an analogue intraocular pressure (IOP) cycle.
Based on the amplitude and on the phase shift of pulsations of retinal vessel wall, the goal is to identify a lead source of the retinal venous pulsations (IOP pulsations, or alternative sources, e.g. cerebrospinal fluid pulsations).
Subjects will be recruited from the environment of the master thesis medical students, colleagues and friends and the informed consent will be handed to them personally. Exclusion criteria will be addressed. One random eye per subject will be selected. On the study day, first the mydriasis drops - phenylephrine + tropicamide - will be applied, then ECG electrodes attached; 20 minutes after the mydriasis drops, the first set of measurements will be performed: RVA recording with ECG gating, and Pascal Dynamic Contour Tonometry (DCT) recording with ECG gating. Ten minutes after this measurements, 100% oxygen 5 liters/min through nasal cannula will be applied for 2 minutes and then the same measurements repeated. Approximate time needed for the whole run - around 60 minutes per subject, including (dis)mounting the ECG electrodes and the mydriasis time.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 20
Known ophthalmological disease, in particular vascular disease.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Experimental arm Retinal Vessel Analyzer recordings with electrocardiographic (ECG) gating Measurement RVA / IOP / with ECG gating
- Primary Outcome Measures
Name Time Method Phase shift between pulsations day 1 No phase shift versus phase shift between the venous amplitude maximum and the IOP pulsation maximum.
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
University Eye Hospital
🇨🇭Basel, Baseö, Switzerland