Skip to main content
Clinical Trials/NCT03892824
NCT03892824Active, not recruitingNot Applicable

Carotid Artery ImPlant for Trapping UpstReam Emboli (CAPTURE 2) for Preventing Stroke in Atrial Fibrillation Patients Taking Oral Anticoagulants

Javelin Medical17 sites in 8 countries100 target enrollmentStarted: April 15, 2019Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Active, not recruiting
Sponsor
Enrollment
100
Locations
17
Primary Endpoint
Number of participants that had Ischemic Stroke and/or Hemorrhagic stroke and/or implantation procedure complications

Study Overview

Brief Summary

This study will assess the safety and performance of the Vine™ Embolic Protection System (embolic filtering device) in atrial fibrillation (AF) patients on top of oral anticoagulants (OAC), and remain at high risk for stroke recurrence. All patients will receive bilateral implants in the common carotid arteries

Detailed Description

The Vine™ filter (Vine™ or implant) is a permanent carotid filter designed for stroke prevention in AF patients taking OAC at high stroke risk (CHA2DS2-VASc ≤ 4 and stroke history). This patient population accounts for ~20% of the entire AF population, which is ~300K/year in the United State and EU. The implant is designed to exclude emboli > 1.4mm in size from reaching the anterior circulation. In AF patients, approximately 80% of strokes are total or partial anterior circulation strokes caused by occlusions of the main branches of the Circle of Willis, mainly M1-2, and rarely A1-2. The diameter of these branches, in the majority of cases, is > 1.5 mm

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Prevention
Masking
None

Eligibility Criteria

Ages
50 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • •Documented AF
  • •CHA2DS2-VASc score ≥ 4 and history of ischemic stroke (including TIA with positive neuro-imaging)
  • •No contra-indication for patient to receive an OAC, either vitamin K antagonist (VKA) or novel oral anticoagulant (NOAC) for the duration of the study
  • •Age > 50 years
  • •Maximal (systolic) CCA diameter range: ≥ 4.8mm and ≤ 9.8mm
  • •CCA accessibility: up to 40mm from skin to CCA center, safe approach
  • •Implantation segment free of atherosclerotic disease as determined by ultrasound imaging
  • •Patient is able and willing to provide informed consent

Exclusion Criteria

  • •Evidence of carotid stenosis > 30% [CCA, internal carotid artery (ICA), or external carotid artery (ECA)]
  • •Evidence of carotid dissection
  • •Pre-existing stent(s) in CCA
  • •Female who is pregnant or who is planning to become pregnant during the course of the study
  • •Life expectancy of less than two years
  • •Active systemic infection
  • •Known sensitivity to nickel or titanium metals, or their alloys
  • •Known hereditary or acquired coagulation disorders
  • •Any planned surgical or endovascular treatment within 30 days after the implantation procedure
  • •A co-morbid disease or condition that could confound the neurological and functional evaluations or compromise survival or ability to complete follow-up assessments* Current use or a recent history of illicit drug(s) use or alcohol abuse (defined as regular or daily consumption of more than four alcoholic drinks per day)
  • •Active participation in another investigational drug or device treatment study
  • •Inability to complete all scheduled follow-up
  • •Any other condition that in the opinion of the investigator may adversely affect the safety of the patient or would limit the patient's ability to complete the study
  • •History of intracerebral hemorrhage (ICH) and/or hemorrhagic stroke
  • •Event of stroke/TIA in the past 14 days

Arms & Interventions

Vine™ Filter + OAC

Experimental

Vine™ Filter in each common carotid artery (CCA) with oral anticoagulant treatment (either vitamin K antagonist (VKA) or novel oral anticoagulant (NOAC)) for the duration of the study

Intervention: Vine™ Embolic Protection System (Device)

Outcomes

Primary Outcomes

Number of participants that had Ischemic Stroke and/or Hemorrhagic stroke and/or implantation procedure complications

Time Frame: 30 days from implantation procedure

Major Adverse Events (MAEs) within 30 days of the final index (implantation) procedure, defined as the composite that includes any of the following: * Any ischemic stroke with ischemic foci confined to the territories of Vine™ implanted arteries * Hemorrhagic stroke or major hemorrhage while receiving additional antithrombotic therapy required for Vine™ implantation * Any Vine™ or Vine™ implantation procedure-related complication that requires surgery or endovascular treatment, or results in death or major disability

Secondary Outcomes

  • Number of participants that had disabling strokes(30 days, one and two years from implantation procedure)
  • Number of observed thrombi on the device(30 days, one and two years from implantation procedure)
  • Number of participants that had Ischemic Stroke and/or Hemorrhagic stroke and/or Device complications.(one and two years from implantation procedure)
  • Number of properly positioned implants(one and two years from implantation procedure)
  • Number of death cases(one and two years from implantation procedure)
  • Number of strokes (any kind)(one and two years from implantation procedure)
  • Number of Implantation success(immediately after the procedure)
  • Number of properly positioned implants(30 days from implantation procedure)

Investigators

Sponsor
Javelin Medical
Sponsor Class
Industry
Responsible Party
Sponsor

Study Sites (17)

Loading locations...

Similar Trials