跳至主要内容
临床试验/NCT04205474
NCT04205474已完成不适用

Aortic Valve Dynamics During Exercise After Valve Sparing Root Replacement Surgery

University Hospital, Ghent1 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2019年12月16日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
20
试验地点
1
主要终点
comparison between peak gradients in mmHg across tricuspid and bicuspid aortic valves

研究概览

简要总结

Aortic valve sparing operations are applied in patients with a non-calcified tricuspid or bicuspid aortic valve associated with a root aneurysm, in order to preserve the valve, and avoid new aortic dilatation by stabilizing the aortic valve anulus with a graft prosthesis.

This results in a normal functioning aortic valve, with a low forward gradient across the left ventricular outflow tract.

Little is known about how the repaired aortic valve behaves in conditions of controlled exercise, and how the gradients across the valve change during exercise.

详细描述

In a cohort of patients operated on since 2000 with a valve sparing operation for aortic root aneurysm in the Department of Cardiac surgery of the University Hospital Ghent, Belgium, and with gradients at rest across the aortic valve of <20mmHg, a graded exercise test on a bicycle (stepwise increase of afterload) will be performed, and the gradient across the aortic valve will be monitored by transthoracic echocardiography at each exercise level. Patients with tricuspid and bicuspid valves will be compared. An age matched, unoperated, and asymptomatic control group with normal functioning tricuspid and bicuspid valves will be examined with the same exercise protocol.

The purpose of the study is the description of the gradients across the aortic valve during exercise, and the discrimination of risk factors that may induce increased gradients.

The hypothesis is that patients with bicuspid valves will demonstrate higher gradients than patients with tricuspid valves, in operated and unoperated individuals.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 60 Years(Adult)
性别
All
接受健康志愿者
是

入选标准

  • •been operated with a valve sparing root procedure in the University Hospital Ghent, Belgium, since 2000
  • •being able to perform an exercise test on a reclining bicycle
  • •normal left ventricular function

排除标准

  • •<18 years or >60 years of age
  • •peak gradient across the aortic valve at rest of >20mmHg
  • •decreased left ventricular function

研究组 & 干预措施

VSRR with tricuspid aortic valve

Active Comparator

Patients with a tricuspid valve that previously underwent a valve sparing root procedure for aortic root aneurysm

干预措施: graded bicycle test (Diagnostic Test)

VSRR with bicuspid aortic valve

Active Comparator

Patients with a bicuspid valve that previously underwent a valve sparing root procedure for aortic root aneurysm

干预措施: graded bicycle test (Diagnostic Test)

结局指标

主要结局

comparison between peak gradients in mmHg across tricuspid and bicuspid aortic valves

时间窗: from 1 year postoperatively

obtained with transthoracic echocardiography during exercise, at each exercise level

Echocardiographic gradients in mmHg and velocity across the aortic valve in m/sec at each exercise level

时间窗: from 1 year postoperatively

obtained with transthoracic echocardiography during exercise- echocardiographic flow velocity across the aortic valve (colour flow Doppler) and in the left ventricular outflow tract (pulsed-wave Doppler) were measured at regular time intervals during grade exercise, and during recovery - examination was recorded digitally

次要结局

  • comparison between gradients across aortic valve in unoperated and operated patients(1 year)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...