Endostapler Sleeve Gastrectomy Study
- Conditions
- Obesity
- Interventions
- Device: Endo GIA Reloads with Tri-Staple TechnologyDevice: AEON Endostapler
- Registration Number
- NCT04617574
- Lead Sponsor
- Lexington Medical Inc.
- Brief Summary
The goal of this prospective, post-market study is to measure AEON™ Endostapler performance for laparoscopic sleeve gastrectomy surgery versus the Endo GIA™ Reloads with Tri-Staple™ Technology from Medtronic.
- Detailed Description
Stapler performance will be evaluated primarily by incidence and degree of staple line bleeding from endoscopic images, evaluated by a blinded third-party. The study will include 60 total consecutive cases of individuals undergoing a planned laparoscopic sleeve gastrectomy (LSG). The LSG procedure will be performed according to institutional standard-of-care and all subjects will undergo standard preoperative evaluation as well as post-operative care.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 60
- Patients undergoing planned laparoscopic sleeve gastrectomy
- Informed consent for study obtained and signed from each subject
- Planned open surgical approach
- Use of staple line reinforcement material (buttress)
- Revision or other bariatric procedure
- Patients with a bleeding disorder: known coagulopathy, or Platelets <100,000, or Partial Thromboplastin Time (PTT) >45sec, or Prothrombin Time (PT) >15sec, or International Normalized Ratio (INR) >1.5
- Patients with active HIV or Hepatitis B
- Patients under the age of 18 on the date of the surgery
- Patients who are pregnant
- Patients using tobacco products within the last 2 weeks prior to surgery date
- Patients using cortisone or related products within the last 2 weeks prior to surgery date
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description Endo GIA Reloads with Tri-Staple Technology Endo GIA Reloads with Tri-Staple Technology Stapling performed with Endo GIA Reloads with Tri-Staple Technology AEON Endostapler AEON Endostapler Stapling performed with AEON Endostapler
- Primary Outcome Measures
Name Time Method Intraoperative Endoscopic Staple Line Bleeding Score Within surgery, after the last stapler firing Intraoperative staple line bleeding score from endoscopic images as measured by the provided Bleeding Severity Scale (1 = No bleeding; 2 = Minimal bleeding; 3= Moderate bleeding; 4 = Excessive bleeding; 5 = Profuse bleeding). A lower value represents a better outcome.
Intraoperative Laparoscopic Staple Line Bleeding Score Within surgery, images captured 10 seconds after the last stapler firing Intraoperative staple line bleeding score from laparoscopic images as measured by the provided Bleeding Severity Scale (1 = No bleeding; 2 = Minimal bleeding; 3= Moderate bleeding; 4 = Excessive bleeding; 5 = Profuse bleeding). A lower value represents a better outcome.
- Secondary Outcome Measures
Name Time Method Number of Participants With Postoperative Leakage Requiring Intervention Within 30-day post-operative period Number of participants with postoperative leakage requiring intervention
Number of Participants With Intraoperative or Postoperative Blood Transfusion Within 72 hours of surgery start time Number of participants with intraoperative or postoperative blood transfusion
Number of Participants With Reported Device-related Adverse Events Within 30-day post-operative period Number of participants with reported device-related adverse events
Number of Participants With Product Malfunction Within surgery Number of participants with product malfunction. Product malfunction means any occurrence during the surgery where the stapler does not perform as intended.
Trial Locations
- Locations (1)
Holyoke Medical Center
🇺🇸Holyoke, Massachusetts, United States