Hyperpolarized Pyruvate Imaging of Glioma: Imaging-Pathological Correlation
试验速览
- 阶段
- 1 期
- 状态
- 招募中
- 入组人数
- 13
- 试验地点
- 1
- 主要终点
- Successful collection of hyperpolarized pyruvate magnetic resonance (MR) (HMR) imaging data
研究概览
简要总结
This trial studies how an imaging agent, hyperpolarized carbon C 13 pyruvate, works in diagnosing glioma in patients with brain tumors. Giving hyperpolarized carbon C 13 pyruvate before an advanced imaging technique called a magnetic resonance spectroscopic imaging (MRSI) scan may help researchers better diagnose glioma in patients with brain tumors.
详细描述
PRIMARY OBJECTIVES:
I. To establish a clinical infrastructure for performing hyperpolarized carbon C 13 pyruvate (hyperpolarized 13-C-pyruvate) imaging in the human brain at MD Anderson.
SECONDARY OBJECTIVES:
I. To assess the correlation between conversion rate of hyperpolarized pyruvate to lactate (kpl) values and Ki-67 quantitation in the tumor.
II. To compare kpl values between tumor and normal brain within patient. III. To assess the association between kpl values and pathology results, including conventional, diffusion, perfusion, and permeability imaging.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 19 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Written informed consent will be obtained from each participants including healthy volunteers.
- •Healthy volunteers will not have contra-indications to MR scanning, but will otherwise not be subject to other selection criteria.
- •All patients will be enrolled in study # 2011-0370, the Stereotactic RadPath trial
- •Patient is >18 years old, agrees to participate in the clinical study and to complete all required visits and evaluations. The pediatric population has a different disease profile from the glioma patients we hope to recruit. To reduce heterogeneity in the patient population we will not consider patients younger than 18 for this study.
- •Patient is a candidate for cerebral tumor resection with lesion suspected to be or previously biopsy proven to be a primary brain tumor.
- •Patient is able to understand and give consent to participation in the study.
- •Patient agrees to undergo, prior to the procedure, magnetic resonance imaging (MRI, within 14 days and preferably with 3 days of the planned procedure) with perfusion, diffusion and spectroscopic imaging.
- •Patient has a GFR >
- •In patients with moderate renal failure (GFR 30-60), an alternate injection with 2 times half-dose multihance (gadobenate dimeglumine) or gadovist (gadobutrol) will be considered, if a contrast exam is deemed clinically necessary.
- •Specifically for this Study: Patient is willing to give signed informed consent for C13-Pyruvate MR Spectroscopy.
排除标准
- •Healthy volunteers will be screened using same process but will otherwise not be subject to other selection criteria.
- •The patient is found to have unfavorable anatomy to indicate that stereotactic biopsy could not be safely performed.
- •Pacemakers, electronic stimulation, metallic foreign bodies and devices and/or other conditions that are not MR safe, which include but are not limited to: • electronically, magnetically, and mechanically activated implants • ferromagnetic or electronically operated active devices like automatic cardioverter defibrillators and cardiac pacemakers • metallic splinters in the eye • ferromagnetic hemostatic clips in the central nervous system (CNS) or body • cochlear implants • other pacemakers, e.g., for the carotid sinus • insulin pumps and nerve stimulators • non-MR safe lead wires • prosthetic heart valves (if dehiscence is suspected) • non-ferromagnetic stapedial implants • pregnancy • claustrophobia that does not readily respond to oral medication
- •Prior brain tumor treatment, including surgical resection, radiation therapy or chemotherapy for a primary brain neoplasm. Previous biopsy will not disqualify the patient from participation. Remote history (> 6month) of non-CNS malignancy in remission, without evidence of current/ prior brain metastasis, will also not disqualify patient from participating.
- •History of cardiac arrhythmia
研究组 & 干预措施
Diagnostic (carbon C 13 pyruvate, MRSI)
Patients receive hyperpolarized carbon C 13 pyruvate IV over 10-20 seconds and then undergo an MRSI scan.
干预措施: Magnetic Resonance Spectroscopic Imaging (Procedure)
Diagnostic (carbon C 13 pyruvate, MRSI)
Patients receive hyperpolarized carbon C 13 pyruvate IV over 10-20 seconds and then undergo an MRSI scan.
干预措施: Hyperpolarized Carbon C 13 Pyruvate (Drug)
结局指标
主要结局
Successful collection of hyperpolarized pyruvate magnetic resonance (MR) (HMR) imaging data
时间窗: Up to 1 year
The kpl values will be calculated for each biopsy site, tumor border zone, and the contralateral side.
次要结局
- Tumor kpl values(Up to 1 year)
- Normal brain kpl values(Up to 1 year)
- MR imaging findings(Up to 1 year)
- Ki-67 quantitation(Up to 1 year)
- Pathology results(Up to 1 year)
- Genomic findings(Up to 1 year)