Does the End-tidal Concentration Estimate the Blood Concentration of Inhalational Anaesthetics During One-lung Ventilation?

University of Edinburgh1 个研究点 分布在 1 个国家目标入组 19 人开始时间: 2016年8月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
19
试验地点
1
主要终点
Correlation Between Blood and End-tidal Isoflurane or Sevoflurane Concentration During One-lung Ventilation

研究概览

简要总结

The aims of the study is to determine if end-tidal concentrations of the anaesthetic gases isoflurane and sevoflurane as measured by a standard gas monitor are related to the blood levels during one-lung ventilation.

详细描述

Measurement of the anaesthetic gases such as isoflurane and sevoflurane allow anaesthetists to gauge their blood levels and in turn their brain levels and so help assess how deep the patient is under anaesthesia. These measurements, made as the patient breathes out, are known as end-tidal concentrations of anesthetic gases and are routinely made with gas monitors. Measurement of blood levels of anaesthetic gases is possible but infrequently done as it is time-consuming, expensive, and requires a scientist in a laboratory with specialized equipment. Depth of anaesthesia is assessed using clinical signs along with end-tidal concentrations though more recently it can be assessed by monitoring the brain's electrical waves. This technique remains controversial.

Mechanically supporting the patient's breathing using only one of the two lungs, known as one-lung ventilation, is used in lung surgery to allow the surgeon to gain access to one side of the chest whilst the anaesthetist supports the lung on the other side. One-lung ventilation markedly alters the exchange of gases in the lungs, including anaesthetic gases. Because of this derangement, it is not known if the end-tidal concentrations are related to blood levels of anaesthetic gases during this type of mechanical ventilation. The aims of the study is to determine if end-tidal concentrations of anaesthetics as measured by a standard gas monitor are related to the blood levels of the gases isoflurane and sevoflurane during one-lung ventilation.

Patients over 18 years old undergoing planned lung surgery with one-lung ventilation and anaesthesia with isoflurane or sevoflurane, and who have a routine tube inserted into an artery in their wrist to monitor blood pressure will be recruited for the study. During the study, two blood samples the size of two teaspoons each will be taken from the tube in the artery and two end-tidal concentration recordings.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Over the age of 18
  • Admitted for elective thoracic surgery using one-lung ventilation obtained by the use of a double-lumen endotracheal tube or bronchial blocker.
  • Elective surgery planned between 1 August and 30 November 2016
  • Planned insertion of an arterial cannula by anaesthetist for routine monitoring of systemic arterial pressure
  • Planned inhalational anaesthesia technique with isoflurane or sevoflurane.
  • Patients who have provided consent to take part in the study

排除标准

  • Patients under the age of 18
  • History of malignant hyperthermia
  • Emergency thoracic surgery
  • Patients who have not consented to take part in the study

结局指标

主要结局

Correlation Between Blood and End-tidal Isoflurane or Sevoflurane Concentration During One-lung Ventilation

时间窗: 10 minutes after start of one-lung ventilation

The significance of the correlation between blood and end-tidal isoflurane or sevoflurane concentration during one-lung ventilation

次要结局

  • Correlation Between Bispectral Index (BIS) and End-tidal Isoflurane or Sevoflurane Concentration During One-lung Ventilation.(10 minutes after start of one-lung ventilation)