A Study to Evaluate the Safety and Effectiveness of TRIGEN™ INTERTAN™ (10S Models)

Withdrawn
Conditions
Femoral Fractures
Hip Fractures
Registration Number
NCT04865146
Lead Sponsor
Smith & Nephew Medical (Shanghai) Ltd
Brief Summary

This is a post-market study to evaluate the revision rate of femoral fractures, treated with INTERTAN 10S Nails at one-year post-operation. The study will enroll Approximately 180 subjects with femoral fractures, Approximately 7 sites are involved. The study duration will be Approximately 36 months (6 months start-up, 1 year enrollment, 1 year follow-up, 6 months closeout/study report).

Detailed Description

Background:

The INTERTAN nail was designed to improve upon existing intramedullary nail systems. INTERTAN nails utilize two interlocking screws, thereby improving controlled intertochanteric fracture compression and post-surgical stability.

Purpose:

Evaluate the revision rate of femoral fractures, treated with INTERTAN 10S Nails at one-year post-operation

Objectives:

* Primary Objective: To evaluate the revision rate for any reason of femoral fractures, treated with INTERTAN 10S Nails at one year post-operation

* Secondary Objective: To generate safety and effectiveness evidence for INTERTAN 10S Nails via the collection of functional outcomes, quality of life, and safety data

Research participants / locations:

The study will enroll Approximately 180 subjects with femoral fractures, Approximately 7 sites in China are involved.

Recruitment & Eligibility

Status
WITHDRAWN
Sex
All
Target Recruitment
Not specified
Inclusion Criteria
  • Subjects who sign the informed consent form (ICF) voluntarily.
  • Subjects who have a femoral fracture and are scheduled for repair using an INTERTAN 10S Nail.
  • Male or female subjects aged 18 years or older, with mature bone development at time of implantation.
  • Subjects who agree to follow all study visits and procedures.
Exclusion Criteria
  • Subjects with known hypersensitivity to the device or implant materials.
  • Subjects in which use of the device would cross open epiphyseal plate(s).
  • Subjects with complex intertrochanteric and femoral neck fractures.
  • Subjects with an existing condition that predisposes them to a poor outcome, such as blood supply limitations, insufficient bone quality or quantity, obliterated medullary canal, previous infections or other conditions which tend to retard healing.
  • Subjects not suitable for operation due to obvious local or systemic infection.
  • Subjects who are unable to tolerate anesthesia and surgery due to cardiopulmonary failure or other serious diseases.
  • Subjects with a congenital or acquired bony deformity.
  • Subjects with Body Mass Index (BMI) of ≥ 35.
  • Subjects with hypovolemia, hypothermia, or coagulopathy.
  • Subject is immunosuppressed, has an autoimmune disorder or an immunosuppressive disorder. For examples, subjects are on immunosuppressive therapy (cortisol at large dose, cytotoxic drugs, antilymphocytic serum or irradiation at large doses) or has acquired immunodeficiency syndrome (AIDS).
  • Subjects with any existing hardware that would preclude the use of the nail.
  • Subjects with mental or emotional conditions or any other clinical conditions that, in the opinion of the Investigator, would preclude cooperation and compliance with the rehabilitation regimen.
  • Subjects with medical or physical condition that, in the opinion of the Investigator, would preclude safe subject participation in the study.
  • Subject is a woman who is pregnant or lactating, or intends to become pregnant during the course of the study follow-up.
  • Subjects who have participated in any other clinical trial within 3 months of Screening.
  • Subjects who have participated previously in this clinical study and were withdrawn for any reason.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
The Revision Rate1 year

To evaluate the revision rate for any reason of femoral fractures, treated with INTERTAN 10S Nails at one year post-operation.

Secondary Outcome Measures
NameTimeMethod
EuroQol 5-Dimension 5-Level (EQ-5D-5L)Pre-operative, 6 weeks, 3 months, 6 months, & 1 year

The EQ-5D-5L is a standardized instrument for use as a measurement of health outcome. It consists of a descriptive system with 5 dimensions (mobility, self-care, usual activities, pain/discomfort and anxiety/depression), which are each assigned five levels (no problems, slight problems, moderate problems, severe problems and extreme problems), as well as, a Visual Analogue Scale (VAS) where subjects indicate a numerical value from 1-100 where 0 is the worst imaginable health state and 100 is the best imaginable health state.

The respondent is asked to indicate his/her health state by ticking (or placing a cross) in the box against the most appropriate statement in each of the dimensions. This decision results in a 1- digit number expressing the level selected for that dimension. The digits for 5 dimensions can be combined in a 5-digit number describing the respondent's health state.

Radiographic AssessmentPre-operative, 6 weeks, 3 months, 6 months, & 1 year

Full-length standing radiographs, standard anteroposterior (AP), and lateral radiographs of lower extremities taken prior to surgery and at all follow-up time points to identify the presence of bone healing result, normal fracture healing and disturbed fracture healing.

Harris Hip Score (HHS)6 weeks, 3 months, 6 months, & 1 year

The Harris Hip Score is a joint specific score that consists of 10 items covering domains of pain (1 item, 0-44 points), function (7 items, 0-47 points), functional activities, absence of deformity (1 item, 0 or 4 points), and hip range of motion (2 items, 0-5 points). Scores range from 0 (worst) to 100 (best).

Intraoperative ComplicationsIntraoperative

Documentation of any complications related to the implantation of the device. Potential complications of this type of surgery include, but are not limited to, those listed below.

* Loosening, bending, cracking or fracture of the implant components

* Limb shortening or loss of anatomical position, accompanied with bone nonunion or with rotation or angulated malunion

* Infections, both deep and superficial

* Irritational injury of soft tissues, including impingement syndrome

* Supracondylar fractures from retrograde nailing

* Macrophage and foreign body reactions adjacent to implants

Length of StayDuring hospitalization

Length of stay in days participant spends in hospital.

Time to Return to Full Weight-BearingPost-operatively through study completion, approximately 12 months

To evaluate the bone healing during each visit by achieving return to full weight-bearing.

Time to UnionThrough study completion, approximately 1 year

To evaluate the bone healing during each visit by achieving radiographic union.

Trial Locations

Locations (7)

The Second Affiliated Hospital of Anhui Medical University

🇨🇳

Hefei, Anhui, China

The Third Hospital of Hebei Medical University

🇨🇳

Shijiazhuang, Hebei, China

Tang Shan 2rd Hospital

🇨🇳

Tangshan, Hebei, China

The First Affiliated Hospital of Dalian Medical University

🇨🇳

Dalian, Liaoning, China

Peking University Third Hospital

🇨🇳

Beijing, China

Shanghai 6th People Hospital

🇨🇳

Shanghai, China

Shanghai Tenth People's Hospital

🇨🇳

Shanghai, China

The Second Affiliated Hospital of Anhui Medical University
🇨🇳Hefei, Anhui, China

MedPath

Empowering clinical research with data-driven insights and AI-powered tools.

© 2025 MedPath, Inc. All rights reserved.