MedPath

PEEK Vs Titanium for All-on-4 Prosthesis

Not Applicable
Completed
Conditions
Satisfaction, Patient
Bite Force
Registration Number
NCT06700733
Lead Sponsor
Mansoura University
Brief Summary

This crossover clinical study will examine the impact of the framework material of implant-supported prostheses on patient satisfaction and Oral Health-Related Quality of Life (OHRQoL) with mandibular All-on-4 implant distribution. The trial will investigate subject satisfaction, OHRQoL as the primary outcome, and chewing efficiency and maximum bite force as secondary outcomes for different framework materials used in implant-supported screw-retained restorations. The first null hypothesis states no significant difference in patient satisfaction and OHRQoL between the tested prostheses. Additionally, the second null hypothesis states no significant difference in chewing efficiency and maximum bite force between the tested prostheses.

Detailed Description

Prosthetic steps

1. For each patient, an abutment-level impression will be made, and the resultant cast will be 3D scanned for CAD/CAM construction of a PEEK superstructure with abutments.

2. A verification jig will be constructed to ensure the accuracy of the cast.

3. The final prosthesis will be virtually planned by using the Exo-Cad software.

4. The final prosthesis will be milled in Duralay polymerized resin disk, and the prosthesis resin pattern will be tried intra-orally for passive fit using a screw test.

5. For the PP, The PEEK framework will be constructed, the fit of the PEEK framework will be verified intraorally, and the final screw-retained prosthesis will be constructed of PMMA teeth and a visiolign pink composite estimating the gingival tissue.

6. For the TP, the framework will be milled from Ti blocks according to the virtual design of the final prosthesis framework. PMMA teeth then will be cemented, and the final prosthesis will be screwed.

Evaluation

1. Patient satisfaction (VAS) Patient satisfaction will be evaluated using a questionnaire based on a visual analog scale (VAS).(21) Patients will be asked to mark their answer (amount of satisfaction) on a 100-mm line (with zero referring to not satisfied at all and 100 referring to completely satisfied). The mean of the answers (length of the lines from zero to the marks in mm) for each question was subjected to statistical analysis.

2. Oral health-related quality of life (OHIP-14) The oral health impact profile (OHIP-14) questionnaire was used to measure OHRQoL. The full OHIP questionnaire consisted of 49 items covering seven main domains: functional limitation, physical pain, psychological discomfort, physical disability, psychological disability, and social disability. The OHIP-14 questionnaires were translated into Arabic by linguistic professionals who worked in collaboration with the authors to prepare the final version.

3. Evaluation of masticatory efficiency: Chewing efficiency will be evaluated using the color mixing ability test.

4. Evaluation of maximum bite force (BF): A digital BF transducer will be used to evaluate maximum BF in Newton (N).

Recruitment & Eligibility

Status
COMPLETED
Sex
Male
Target Recruitment
18
Inclusion Criteria

The inclusion criteria include

  • healthy male patients free from systemic diseases that may affect bone health, such as uncontrolled diabetes mellitus and osteoporosis.
  • implants placed with the All-on-4 concept in the mandible.
Exclusion Criteria
  • The exclusion criteria: the patients with a history of parafunctional habits (bruxism and clenching), smoking, and alcoholism

Study & Design

Study Type
INTERVENTIONAL
Study Design
CROSSOVER
Primary Outcome Measures
NameTimeMethod
patient satisfaction3 month

Patient satisfaction will be evaluated using a questionnaire based on a visual analog scale

chewing efficiency3 month

Chewing efficiency will be evaluated using the color mixing ability test

Secondary Outcome Measures
NameTimeMethod
Oral health-related quality of life (OHRQoL)3 month

The oral health impact profile (OHIP-14) questionnaire was used to measure OHRQoL.

maximum bite force (BF)3 month

A digital BF transducer will be used to evaluate maximum BF in Newton (N)

Trial Locations

Locations (1)

Khloud Ezzat

🇪🇬

Mansoura, Egypt

© Copyright 2025. All Rights Reserved by MedPath