Interest of a Tongue Strength Measurement in the Screening for Sarcopenia in Hospitalized Elderly Patients
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 110
- 试验地点
- 1
- 主要终点
- Tongue strength
研究概览
简要总结
Sarcopenia is a syndrome characterized by a progressive and generalized loss of skeletal muscle mass, strength and function that increases the risk of physical dependence, impaired quality of life and mortality. This is a major public health problem. Indeed, its prevalence has been estimated at 63.8% for elderly patients hospitalized in acute geriatric unit.
Several methods of sarcopenia screening exist at present. The European Working Group on Sarcopenia in Older People (EWGSOP) proposes to carry out three examinations for the diagnosis of sarcopenia: the Dual-Energy X-ray Absorptiometry (DEXA) test and two motor tests (walking speed and hand test). These measurements have already been evaluated and validated. They are reliable, inexpensive and easily achievable in clinical routine.
Recent studies have shown that decreased muscle mass and / or strength could be associated with dysphagia. Indeed, many muscles of the head and neck are simultaneously solicited for swallowing coordination. This suggests that a reduction in the mass or strength of these muscles could impact the swallowing function. The investigator's hypothesize that loss of lingual muscle strength may be associated with sarcopenia. The study will measure the tongue strength using the Iowa Oral Performance Instrument (IOPI) in a geriatric population with or without sarcopenia.
- Determine the incidence of lingual hypotonia in hospitalized elderly sarcopenia patients.
- To compare the sensitivity, the specificity of the measurement of the force of the tongue with the usual measures proposed by the EWGSOP in the context of screening for sarcopenia.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 65 Years 至 —(Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients hospitalized in an acute geriatric unit within the CHU Brugmann.
排除标准
- 未提供
结局指标
主要结局
Tongue strength
时间窗: 6 months
The Iowa Oral Performance Instrument is a validated device for assessing the strength of the tongue. This involves placing the tip of a tube in the mouth and asking the patient to exert pressure on it. Thus, a pressure measurement expressed in kPa makes it possible to objectify the tongue strength.
次要结局
- Albumin concentration(6 months)
- Skeletal Mass Muscle Index(6 months)
- Pre-Albumin concentration(6 months)
- Hand grip strength(6 months)
- Minimal nutritional assessment (MNA-SF) score(6 months)
- Mini Mental State Examination (MMSE) score(6 months)
- Walking speed(6 months)
研究者
Murielle Surquin
Head of clinic
Brugmann University Hospital