Smart Box Accompanied With OT Equator Attachment in Retaining Immediately Loaded Inclined Implant Assisted Overdenture for Atrophic Maxilla

Hams Hamed Abdelrahman1 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2018年3月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
10
试验地点
1
主要终点
Change in Implant Stability

研究概览

简要总结

The aim of the present study is to clinically and radiographically evaluate the effect of the use of recently developed Smart Box accompanied with OT Equator attachment in retaining of the inclined implant assisted overdenture for atrophic maxilla and to compare the vertical bone changes around axial implants with OT Equator attachment and inclined implants with smart box attachment radiographically using CBCT

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
30 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Male patients with comparable age (30- 65 years).
  • All patients should have retruded, posteriorly atrophic completely edentulous maxilla with sinus pneumatization leaving less than 7mm bone height posteriorly and a sufficient amount of bone in the inter bicuspids region.
  • Opposing mandibular dentate arch including bilateral posterior teeth.
  • All patients should have an adequate zone of keratinized mucosa.
  • All patients should be free from any intra-oral or systemic diseases that would otherwise affect the osseointegration of dental implants.
  • All patients should be well motivated, cooperative, and with adequate manual dexterity necessary to place and remove removable implant prosthesis to provide adequate oral hygiene around the endosseous implants.

排除标准

  • Patients with flabby maxillary ridges.
  • Patients who are unwilling to accept implant overdentures as a treatment modality.
  • Patients with temporomandibular and neuromuscular disorders.

结局指标

主要结局

Change in Implant Stability

时间窗: at baseline and 9 months

The Osstell unit records a numeric value of 1-100 which is referred to as the implant stability quotient (ISQ)

Change in Clinical Attachment level

时间窗: Baseline, 3 months, 6 months, 9 months

It is the distance from the junction implant/abutment to the most apically probable portion, in millimeters

Change in alveolar bone level

时间窗: at baseline and 9 months

The level of alveolar bone around each abutment will be evaluated using CBCT.

change in peri-implant probing depth

时间窗: Baseline, 3 months, 6 months, 9 months

The peri-implant sulcus depth will be measured using a graduated plastic periodontal probe.

次要结局