跳至主要内容
临床试验/NCT03787316
NCT03787316已完成不适用

The Effects of Custom-made Insoles on Foot Pressure Redistribution and Spatio - Temporal Gait Parameters in Sever Disease

Acibadem University1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2019年2月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
40
试验地点
1
主要终点
Pain - Visual Analogue Scale-

研究概览

简要总结

The aim of this study was to investigate the effect of specially produced insoles on biomechanical and gait parameters in children with Sever's disease.

详细描述

Introduction: Sever's disease or calcaneal apophysitis is common in pediatric and adolescent patients and characterized by heel pain. Inflammation of apophysis in children of growing age causes microabrasion in bone cartilage joint. At the same time, the disease affects the self-limitation and affects the maturation of calcaneus.Sever's disease is an overuse syndrome and was described by James Warren Sever in 1912. The prevalence of Sever's disease varies between 2% and 16%.Sever's more common in children aged 8 - 15 years, but it was reported that heel pain increased during or after activity.This results in a shortening of the stance phase to remove the limb to avoid heel strikes during walking. Increased tension in the Achilles tendon and plantar fascia is affected by the mobility of the medial longitudinal arch of the foot and increases loading on the calcaneal cartilage. Stimulates foot alignment to pronation.

Different treatment have been described in Sever's disease. In the treatment program, stretching, strengthening exercises and ice application are recommended especially for gastrocnemius muscle and extensor muscle group.The traditional treatment approach is the restriction of the child's physical activity and sporting activities and rest until the symptoms have passed. In addition, orthoses can be used to treat the heel amplifier, anatomical dysregulation dominated by standing pronation. There is no previous study in order to investigate the effect of the specially produced insoles on the Sever's disease by changing the foot pressure center and the effect of the pronation on the gait parameters.

Subjects and methods:

The study is planned to be done with physical examination and radiological imaging of the patients who are between 8 and 15 years of age and diagnosed with Sever's disease. After the first physical examination evaluation, the foot rotation, step length, stance phase percentage, swing phase percentage, cadence and velocity parameters will be recorded with Zebris FDM -T (Force Distribution Measurement Treadmill) system. Zebris is a name of company in Germany.

Zebris Medical Limited ) is an innovative company that has been successful for many years in the development and production of 3D motion analysis and force measurement technologies for biomechanics. When the treadmill is in static and dynamic condition, strong pressure distribution measurement will be taken and personalized insole production according to foot pressure map will be done by orthosis prosthesis technician with Arch drafters Orthotics technology. After physiotherapist,decision, it will be delivered to the patients with the condition of being used outside and inside the home. Measurements related to pressure and gait parameters will be repeated after 4 weeks of use and home exercise (strengthening, stretching and eccentric exercise for the anterior lateral - posterior compartment of the foot ).

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
8 Years 至 15 Years(Child)
性别
All
接受健康志愿者

入选标准

  • Aged between 8-15 years
  • Calcaneal apophysitis with clinical symptoms and radiographic screening
  • Positive squeeze test sign
  • Heel pain more than 2 weeks

排除标准

  • Intermittent heel pain to exclude plantar fasciitis pathology
  • Another pathology within the same or the other foot for example fracture, achilles tendinitis and calcaneal bursitis
  • Another pain symptom within the other part of the extremity

结局指标

主要结局

Pain - Visual Analogue Scale-

时间窗: 4 weeks

Visual Analogue Scale is one of the simple and common methods used in pain assessment. Self reported pain intensity during the rest and the activity measured by 0-10 centimeter chart. Visual Analogue Scale (VAS), where 0 indicates no pain or best and 10 indicates the most intense pain imaginable or worst. The patient will mark the severity of the pain on a 10 cm long chart.

Step length (centimeter- cm)

时间窗: 4 weeks

Step length (cm), will be evaluated by Zebris (Zebris Medical Limited - Germany) FDM (Force distribution measurement ) System. Participants will walk barefoot on the Zebris FDM (Zebris Medical Limited, Germany) treadmill system. Aim of the system analyzes gait of the patients. The system is comprised of a capacitance-based pressure platform within a treadmill..When the person is standing steadily or on the walking belt, the sensors can receive reactive and normal force measurement in three dimensions with 120Hertz (Hz) frequency. Timing can be monitorized. Temporal and distance recording are taken while the patient is walking and in a static position.

step time (second - s)

时间窗: 4 weeks

step time ( s) will be evaluated by Zebris (Zebris Medical -Limited -, Germany) FDM (Force distribution measurement ) System. Participants will walk barefoot on the Zebris FDM (Zebris Medical Limited, Germany) treadmill system. Aim of the system analyzes gait of the patients. The system is comprised of a capacitance-based pressure platform within a treadmill..When the person is standing steadily or on the walking belt, the sensors can receive reactive and normal force measurement in three dimensions with 120Hertz (Hz) frequency. Timing can be monitorized. Temporal and distance recording are taken while the patient is walking and in a static position.

Stride length (centimeter -cm)

时间窗: 4 weeks

Stride length (cm) will be evaluated by Zebris (Zebris Medical Limited -, Germany) FDM (Force distribution measurement ) System. Participants will walk barefoot on the Zebris FDM (Zebris Medical Limited, Germany) treadmill system. Aim of the system analyzes gait of the patients. The system is comprised of a capacitance-based pressure platform within a treadmill..When the person is standing steadily or on the walking belt, the sensors can receive reactive and normal force measurement in three dimensions with 120Hertz (Hz) frequency. Timing can be monitorized. Temporal and distance recording are taken while the patient is walking and in a static position.

Step width (centimeter-cm),

时间窗: 4 weeks

step width (cm),will be evaluated by Zebris (Zebris Medical Limited -, Germany) FDM (Force distribution measurement ) System. Participants will walk barefoot on the Zebris FDM (Zebris Medical Limited, Germany) treadmill system. Aim of the system analyzes gait of the patients. The system is comprised of a capacitance-based pressure platform within a treadmill..When the person is standing steadily or on the walking belt, the sensors can receive reactive and normal force measurement in three dimensions with 120Hertz (Hz) frequency. Timing can be monitorized. Temporal and distance recording are taken while the patient is walking and in a static position.

Stride time (second - s),

时间窗: 4 weeks

Stride time (s), will be evaluated by Zebris (Zebris Medical -Limited -, Germany) FDM (Force distribution measurement ) System. Participants will walk barefoot on the Zebris FDM (Zebris Medical Limited, Germany) treadmill system. Aim of the system analyzes gait of the patients. The system is comprised of a capacitance-based pressure platform within a treadmill..When the person is standing steadily or on the walking belt, the sensors can receive reactive and normal force measurement in three dimensions with 120Hertz (Hz) frequency. Timing can be monitorized. Temporal and distance recording are taken while the patient is walking and in a static position.

Cadence (steps/min)

时间窗: 4 weeks

Cadence (steps/min) will be evaluated by Zebris (Zebris Medical -Limited -, Germany) FDM (Force distribution measurement ) System. Participants will walk barefoot on the Zebris FDM (Zebris Medical Limited, Germany) treadmill system. Aim of the system analyzes gait of the patients. The system is comprised of a capacitance-based pressure platform within a treadmill..When the person is standing steadily or on the walking belt, the sensors can receive reactive and normal force measurement in three dimensions with 120Hertz (Hz) frequency. Timing can be monitorized. Temporal and distance recording are taken while the patient is walking and in a static position.

次要结局

未报告次要终点

研究者

发起方
Acibadem University
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验