HYdrogel Coil Versus Bare Platinum Coil in Recanalization Imaging Data Study
- Conditions
- Subarachnoid HemorrhageIntracranial Aneurysm
- Registration Number
- NCT01516658
- Lead Sponsor
- Kobe City General Hospital
- Brief Summary
HYBRID study is prospective randomized open label controlled multi center trial, to compare Hydrocoil and bare platinum coil for recanalization after endovascular treatment of intracranial aneurysms.
- Detailed Description
At least one Hydrocoil have to use in Hydrocoil arm, and only bare platinum coil have to use in Control arm.
Primary endpoint is recanalization within 1 year after embolization, and secondary endpoint are:
1. aneurysmal rupture within 1 year after embolization
2. any event within 30 days after embolization
3. recanalization within 6 months after embolization
4. aneurysmal retreatment within 1 year after embolization
5. aneurysmal rupture and any death within 1 year after embolization
6. any stroke within 1 year after embolization
7. any stroke, death hemorrhagic event, aneurysmal recanalization or retreatment within 1 year after embolization
8. change in aneurysmal occlusion
9. any comlicaion within 1 year after embolization
10. %length of Hydrocoil, maximum diameter of aneurysm, volume embolization ratio.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 431
- saccular intracranial aneurysm
- endovascular treatment scheduled within 60days after consent
- 20-79 years old
- unruptured, chronic SAH or acurte SAH Grade 1-III
- 7-20mm in size
- 1 year follow up possibel
- independent (mRS 0-2)
- document consent
- previous endovascular treated
- additional aneurysm scheduled of endovascular treatment
- pregnant
- ineligible for study
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Primary Outcome Measures
Name Time Method recanalization within 1 year after embolization 1 year
- Secondary Outcome Measures
Name Time Method aneurysmal retreatment within 1 year after embolization 1 year any stroke within 1 year after embolization 1 year any stroke, death hemorrhagic event, aneurysmal recanalization or retreatment within 1 year after embolization 1 year aneurysmal rupture within 1 year after embolization 1 year any event within 30 days after embolization 30 days change in aneurysmal occlusion 1 year any complicaion within 1 year after embolization 1 year aneurysmal rupture and any death within 1 year after embolization 1 year
Related Research Topics
Explore scientific publications, clinical data analysis, treatment approaches, and expert-compiled information related to the mechanisms and outcomes of this trial. Click any topic for comprehensive research insights.
Trial Locations
- Locations (2)
Nakamura Memorial Hospital
🇯🇵Sapporo, Hokkaido, Japan
Kobe City General Hospital
🇯🇵Kobe, Hyogo, Japan
Nakamura Memorial Hospital🇯🇵Sapporo, Hokkaido, Japan