In Vivo Comparison of Kinematics for Subjects Implanted With a Press Fit Condylar Sigma Rotating Platform or Fixed Bearing Total Condylar III Prothesis

The University of Tennessee, Knoxville3 个研究点 分布在 1 个国家目标入组 22 人开始时间: 2011年2月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
22
试验地点
3
主要终点
In Vivo Linear Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.

研究概览

简要总结

The objectives of this study are four-fold:

  1. To determine the three-dimensional, in vivo kinematics for subjects having either a fixed- or mobile-bearing Press Fit Condylar (PFC) Sigma Total Condylar III Prosthesis, comparing the in vivo kinematics to determine if one implant type leads to a benefit for the patient.
  2. To determine if bearing mobility occurs in PFC Sigma Rotating Platform Total Condylar III Prosthesis under in vivo, weight-bearing conditions during multiple activities (gait, stair descent, deep knee bend and chair rise).
  3. To determine if there is a correlation between in vivo kinematic data obtained using fluoroscopy, electromyography (EMG) and ground reaction force (GRF) data and determine if variability occurs between these two TKA types.
  4. To determine if a clinical benefit is either visibly detected (video camera) or quantifiably determined (questionnaire) for either TKA type.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Retrospective

入排标准

年龄范围
40 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients must be at least three months post-operative.
  • Potential subjects will have a body weight of less than 250 lbs.
  • Candidates must have had a HSS score >90 post-operatively.
  • Patients must have passive flexion of at least
  • All potential subjects will have a Press Fit Condylar (PFC) Rotating Platform Total Condylar III Prosthesis (Depuy Orthopaedics, Warsaw, IN) or fixed-bearing Total Condylar III Prosthesis.
  • Must be willing to sign both Informed Consent and HIPAA forms.

排除标准

  • Pregnant females.
  • Patients that do not meet study requirements.

结局指标

主要结局

In Vivo Linear Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.

时间窗: March 2013

The values that were reported indicate the motion of the contact point from the start of the activity to the end of the activity. If the point translated forward (anteriorly) atop the tibial tray, the number was reported as positive. If the point traveled backwards (posteriorly) atop the tibial tray, the number was reported as negative.

In Vivo Angular Kinematics for Fixed-bearing and Rotating Platform (RP) TKA System During 4 Weight-bearing Activities.

时间窗: March 2013

Angular kinematics for fixed bearing and rotating platform TKA system - Axial Rotation The values that were reported indicate the rotation of the femur atop the tibial tray from the start of the activity to the end of the activity. If the femur rotated externally (posterior rollback of the lateral condyle, generally pivoted about the medial condyle), the number was reported as positive. If the femur rotated internally (anterior slide of the lateral condyle, generally pivoted about the medial condyle), the number was reported as negative.