跳至主要内容
临床试验/NCT05855642
NCT05855642尚未招募不适用

The Accuracy And Safety of Trans Pedicular Screw Fixation of The Sub-axial Cervical Spine Using A Triad- Dependent Technique (TDT)

Assiut University0 个研究点目标入组 20 人开始时间: 2023年6月1日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
入组人数
20
主要终点
Radiological accuracy

研究概览

简要总结

The use of the pedicle screw system has become increasingly popular for treating an unstable cervical spine resulting from traumatic, degenerative, inflammatory, and neoplastic conditions. Because the cervical pedicle screw (CPS) has superior bio mechanical stability as the lateral mass screw or trans articular screw , pedicle screws allow for shorter instrumentation with improved spinal alignment. However, CPS insertion is technically demanding because of the anatomical variations in cervical pedicle size, lack of anatomical landmarks, small pedicle diameter, and the large transverse angle of cervical pedicles . The potential risk of injury to neurovascular structures, such as the vertebral artery, spinal cord, or nerve roots, caused by CPS remains a great concern. Therefore, accurate and safe CPS insertion techniques are necessary.

详细描述

The use of the pedicle screw system has become increasingly popular for treating an unstable cervical spine resulting from traumatic, degenerative, inflammatory, and neoplastic conditions. Because the cervical pedicle screw (CPS) has superior bio mechanical stability as the lateral mass screw or trans articular screw , pedicle screws allow for shorter instrumentation with improved spinal alignment. However, CPS insertion is technically demanding because of the anatomical variations in cervical pedicle size, lack of anatomical landmarks, small pedicle diameter, and the large transverse angle of cervical pedicles . The potential risk of injury to neurovascular structures, such as the vertebral artery, spinal cord, or nerve roots, caused by CPS remains a great concern. Therefore, accurate and safe CPS insertion techniques are necessary.

Although a number of studies have evaluated the morphometric of cervical pedicles to support accurate placement of pedicle screws , the results are inconclusive. Therefore, several techniques using lateral fluoroscopy , pedicle axis view by oblique fluoroscopy , laminoframinotomy and computer-assisted navigation systems for CPS insertion have been advocated. Determining an appropriate entry point for screw insertion as well as a proper trajectory angle of the screw on the axial plane is important for successful pedicle screw placement. Here, we present our method using a fashioned triad- dependent technique (TDT) which is a combination of three methods 1-preoperative planning of the selected pedicle using 3-diamentional multi-slice CT to measure pedicle transverse angle (PTA) , pedicle outer diameter(POD)and pedicle trajectory -contralateral lamina angle 2-AP and oblique fluoroscopy to determine pedicle entry point (PEP), parallelism to vertebral end plate and 4 direction cortical violation (medial, lateral, superior, inferior) 3-interlaminar confirmatory key hole for tactile cue of medial ,superior, and inferior borders of the pedicle and related nerve root to evaluate the accuracy and safety of pedicle screw placement in patients with sub axial cervical spine disorders treated using our method.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

性别
All
接受健康志愿者

入选标准

  • traumatic sub axial cervical spine injuries.
  • degenerative cervical spine disorders necessitating cervical fusion

排除标准

  • congenital anomaly of the cervical spine
  • scoliotic deformity of the cervical spine
  • sever osteoporosis
  • congenital malformation of the pedicle.

结局指标

主要结局

Radiological accuracy

时间窗: Immediately post Operative

A. X-ray AP and lateral B. MSCT: Placements of pedicle screws will be assessed using CT data and outcome-based classifications: 2 mm increment classification: * Type 0 (good): Screw within the pedicle medullary canal. * Type 1 (acceptable): Minimal penetration of the pedicle wall by the screw (\<2 mm of medial or lateral cortical perforation or anterior cortex perforation). * Type 2 (unacceptable): Less than half of the diameter of the screw was outside the pedicle wall (2-4 mm of perforation). * Type 3 (grievous): More than half of the diameter of the screw was outside the pedicle wall (\>4 mm of perforation) (spinal cord injury or screw abutting vertebral artery).

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Mahmoud Abdelrahman Saleh El Attar

principal investigator

Assiut University

相似试验